{"product_id":"foxboro-i-a-series-fbm207c-discrete-input-module","title":"Foxboro FBM207c I\/A Series 16-Channel Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro FBM207c (P0917GY) is a high-density 16-channel discrete input module engineered for the I\/A Series Distributed Control System (DCS). This module provides versatile interface capabilities, supporting both voltage monitoring and contact sensing to accommodate a wide range of field switches and relay contacts. Designed for critical industrial environments, the FBM207c ensures high data integrity through robust signal isolation and advanced digital filtering, facilitating real-time monitoring of process interlocks and equipment status.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 independent input channels with configurable digital debounce filtering.\u003c\/li\u003e\n\u003cli\u003eDual-mode operation: Supports both internally powered (contact sense) and externally powered (voltage monitor) configurations.\u003c\/li\u003e\n\u003cli\u003eHigh-speed scanning with software-configurable rates from 1 ms to 250 ms.\u003c\/li\u003e\n\u003cli\u003eOptical isolation (1500 VAC) between field inputs and system logic to protect against transients and surges.\u003c\/li\u003e\n\u003cli\u003eConformal coated to ISA-S71.04 Class G3 standards for protection in harsh environments.\u003c\/li\u003e\n\u003cli\u003eRedundant 2 Mbps Fieldbus communication for high availability in mission-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe FBM207c is widely deployed in utility substations, oil and gas refineries, and heavy manufacturing facilities. It is primarily used for monitoring critical process interlocks, emergency shutdown system status, and general equipment state changes where high-speed, reliable digital input acquisition is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM207c (P0917GY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e16-Channel Discrete Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (Nominal)\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (Optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e1 ms to 250 ms (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 Watts (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is de-energized before inserting or removing the FBM207c from the baseplate.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for mounting on standard I\/A Series baseplates; ensure proper seating to engage the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eAdhere to proper ESD handling procedures when handling the module to prevent damage to sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the termination assembly matches the intended configuration (voltage monitor vs. contact sense) before applying field power.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes the FBM207c require external power for contact sensing?\u003c\/h3\u003e\u003cp\u003eThe module supports both configurations. It can provide internal power for contact sensing or accept external power for voltage monitoring, depending on the specific termination assembly used.\u003c\/p\u003e\u003ch3\u003eIs this module suitable for corrosive environments?\u003c\/h3\u003e\u003cp\u003eYes, the FBM207c is conformal coated to meet ISA-S71.04 Class G3 standards, making it suitable for use in environments with airborne contaminants.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50717059285244,"sku":"FBM207c","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a7c70220-c2c9-4647-999e-72407fc3406f.jpg?v=1785145490","url":"https:\/\/www.electronicplc.com\/products\/foxboro-i-a-series-fbm207c-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}