{"product_id":"foxboro-i-a-series-fbm241c-p0914wm-discrete-i-o-module","title":"Foxboro FBM241c P0914WM Discrete I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro FBM241c (P0914WM) is a high-performance Discrete Input\/Output module engineered for the I\/A Series distributed control system. This module provides 8 discrete input channels and 8 discrete output channels, designed to interface with critical field devices such as solenoid valves, motor starters, and limit switches. Built for demanding industrial environments, the FBM241c features robust optical isolation to protect sensitive system electronics from field-side electrical noise, surges, and transients, ensuring high operational availability in process automation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 discrete input channels and 8 discrete output channels.\u003c\/li\u003e\n\u003cli\u003eOptical isolation for enhanced protection against field-side electrical interference.\u003c\/li\u003e\n\u003cli\u003eSupports 24 VDC input and output signal levels.\u003c\/li\u003e\n\u003cli\u003eCommunicates via the 2 Mbps redundant Module Fieldbus for deterministic data exchange.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each I\/O point to facilitate rapid local diagnostics.\u003c\/li\u003e\n\u003cli\u003eCompact, DIN-rail mountable enclosure designed for high-density cabinet configurations.\u003c\/li\u003e\n\u003cli\u003eFail-safe state management for digital outputs to maintain system integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe FBM241c is widely utilized in process industries, including oil and gas refineries, chemical processing plants, and power generation utilities. It is ideal for applications requiring reliable digital signal processing, such as safety interlocking, sequence control, and monitoring of field-mounted discrete instrumentation.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM241c (P0914WM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete I\/O (8 In \/ 8 Out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 250 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e2 Mbps Redundant Module Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e600 VAC (Field-to-Bus\/Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eClass I Div 2, ATEX Zone 2, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eMount the module on a standard DIN rail within a clean, dry, and vibration-dampened enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to ensure the effectiveness of the module's electrical isolation.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field I\/O connections to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the termination assembly matches the required input\/output configuration (dry contact vs. voltage-sensing).\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the FBM241c module?\u003c\/h3\u003e\u003cp\u003eThe FBM241c is a discrete I\/O module used in the Foxboro I\/A Series system to interface with 8 digital inputs and 8 digital outputs, providing signal conditioning and communication for field devices.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundant communication?\u003c\/h3\u003e\u003cp\u003eYes, the FBM241c communicates with the control processor via the 2 Mbps redundant Module Fieldbus, which provides deterministic and reliable data updates.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum output current per channel?\u003c\/h3\u003e\u003cp\u003eEach output channel is capable of driving external loads up to 250 mA at 24 VDC.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50688760021244,"sku":"FBM241c P0914WM","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_dd187307-3b4a-4d74-9cfa-671cf8e4c46f.jpg?v=1785114211","url":"https:\/\/www.electronicplc.com\/products\/foxboro-i-a-series-fbm241c-p0914wm-discrete-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}