{"product_id":"foxboro-i-a-series-fcm100et-communication-module","title":"Foxboro I\/A Series FCM100Et Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro FCM100Et is a high-performance Ethernet Fieldbus Communication Module designed for the I\/A Series system. It functions as a critical interface that bridges the 100 Mbps Ethernet control network with the specialized Fieldbus used by Field Bus Modules (FBMs). This module is engineered for high-availability industrial environments such as oil and gas refining, chemical processing, and power generation. By facilitating rapid data exchange between the control processor and field I\/O, the FCM100Et ensures real-time deterministic control and monitoring. Its support for redundant fiber optic or copper configurations significantly enhances system resilience, providing a robust communication backbone that minimizes unscheduled downtime and optimizes process safety in mission-critical applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-speed 100 Mbps Ethernet connectivity for I\/A Series control networks.\u003c\/li\u003e\n\u003cli\u003eSupports redundant network topologies via dual Ethernet ports for seamless failover.\u003c\/li\u003e\n\u003cli\u003eIntegrated protocol conversion and data buffering to offload the main control processor.\u003c\/li\u003e\n\u003cli\u003eComprehensive self-diagnostics with front-panel LED status indicators for link activity and hardware health.\u003c\/li\u003e\n\u003cli\u003eCompatible with both 100Base-TX (copper) and 100Base-FX (fiber optic) interfaces.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-availability operation in mission-critical industrial processes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe FCM100Et is widely utilized in distributed control systems (DCS) for continuous process control, including oil and gas refining, petrochemical manufacturing, power generation facilities, and water treatment plants where high-speed, reliable communication between the control layer and field instrumentation is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFCM100Et (P0926GS \/ P0926GU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbps (Ethernet) \/ 2 Mbps (Fieldbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003e100Base-TX (Copper) or 100Base-FX (Fiber Optic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 Watts (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance\u003c\/td\u003e\n\u003ctd\u003e100 m (Copper) \/ 2 km (Fiber Optic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the baseplate connector is clean and free of debris before seating the module.\u003c\/li\u003e\n\u003cli\u003eEnsure proper cable routing for Ethernet connections; keep communication cables away from high-voltage power lines and high-EMI sources to prevent signal interference.\u003c\/li\u003e\n\u003cli\u003eConfirm that redundant network cables are properly terminated according to the specific network topology requirements.\u003c\/li\u003e\n\u003cli\u003eCheck front-panel LEDs after power-up to confirm successful initialization and network link status.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the FCM100Et?\u003c\/h3\u003e\u003cp\u003eThe FCM100Et acts as a communication gateway between the 100 Mbps Ethernet control network and the local Fieldbus cluster, allowing the control processor to communicate with various FBMs in the I\/A Series system.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundancy?\u003c\/h3\u003e\u003cp\u003eYes, the FCM100Et supports redundant network topologies, allowing for dual-path communication to prevent data loss in the event of a cable or switch failure.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum power consumption?\u003c\/h3\u003e\u003cp\u003eThe module has a maximum power consumption of 3.5 Watts.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50731538809084,"sku":"FCM100Et","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ca32ba2d-80cb-4185-83bb-46616ffbbb20.jpg?v=1785236813","url":"https:\/\/www.electronicplc.com\/products\/foxboro-i-a-series-fcm100et-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}