{"product_id":"fx1006-paperless-recorder-yokogawa","title":"FX1006 Paperless Recorder YOKOGAWA","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA FX1006\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFX1006\u003c\/strong\u003e Paperless Recorder, operates as a dedicated hardware component for multi-channel process variable monitoring and data logging within CENTUM or standalone process control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFX1006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e480 mm x 220 mm x 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 to 12 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Interval\u003c\/td\u003e\n\u003ctd\u003e1 s to 125 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e400 MB (Internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Loop Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe FX1006 integrates into industrial control environments by providing high-precision signal acquisition across DCV, TC, and RTD loops. The module architecture ensures channel-to-channel isolation, preventing signal cross-talk and potential ground loops when interfacing with disparate field sensors. Data redundancy is facilitated through network connectivity, allowing for synchronized storage of binary measurement streams across distributed control system nodes, maintaining compliance with standard industrial logging requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum capacity supported for external data logging?\u003c\/p\u003e\n\u003cp\u003eA: The device supports external SD or CF cards with storage capacities up to 32 GB. Ensure the media is formatted to the system-recognized file system before deployment to ensure uninterrupted binary data logging.\u003c\/p\u003e\n\u003cp\u003eQ: Can the scan interval be adjusted during active recording?\u003c\/p\u003e\n\u003cp\u003eA: The scan interval is configurable between 1 s and 125 ms. While settings can be adjusted, verify that the storage media write speed is compatible with high-frequency 125 ms sampling to avoid buffer overflows or data loss.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The unit is designed for 19-inch rack mounting. Ensure the rack rails are properly grounded to the cabinet frame to mitigate electromagnetic interference with the high-precision 5.7-inch TFT LCD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect to a 100-120 V AC source. Use a surge-protected circuit to safeguard the internal memory and processor logic from transient voltage spikes prevalent in industrial power grids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Establish a low-impedance connection to the facility protective earth (PE) bus using the provided chassis terminal. Proper grounding is necessary to achieve the specified +\/- 0.05% DCV accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Operate the recorder in an environment with ambient temperatures between 0 deg C and 55 deg C. Ensure adequate ventilation within the rack to prevent internal thermal accumulation during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50361007571196,"sku":"FX1006","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FX1006.jpg?v=1784510883","url":"https:\/\/www.electronicplc.com\/products\/fx1006-paperless-recorder-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}