{"product_id":"ge-ds200tcdah1bhe-digital-i-o-board","title":"GE DS200TCDAH1BHE Digital I\/O Board","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE DS200TCDAH1BHE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical Digital I\/O board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpeedtronic Mark V gas turbine control system\u003c\/strong\u003e. As a foundational component in the turbine control architecture, this board facilitates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data exchange\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby processing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 digital contact inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital Turbine Building Assembly (DTBA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand managing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 corresponding digital contact outputs\u003c\/strong\u003e. Engineered to provide reliable signaling for complex turbine operations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCDAH1BHE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures precise command execution and status monitoring, essential for maintaining the operational safety and efficiency of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE gas turbine units\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Input\/Output Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 digital contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 digital contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 3-pin connectors, 2 x 50-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 single LED, 1 block of 10 diagnostic LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncludes 8 hardware jumpers for custom setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTesting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated test points for circuit diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Versatility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCDAH1BHE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built to endure the high-demand environment of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial facilities\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erugged construction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotects internal circuitry from typical electrical interference, while the onboard diagnostic indicators and test points significantly reduce troubleshooting time during routine maintenance. By serving as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust bridge\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDTBA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the central control system, this board plays a vital role in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time turbine management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eevent reporting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: How are the 8 jumpers used on this board?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: The onboard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ejumpers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare used to configure the board's operational parameters to match the specific requirements of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V turbine control cabinet\u003c\/strong\u003e. Refer to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem documentation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the correct jumper settings for your application.\u003c\/p\u003e\n\u003ch4\u003eQ: Is this board hot-swappable in a Mark V cabinet?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for component replacement, always follow standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elockout\/tagout\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD (Electrostatic Discharge)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety procedures before handling any circuit board to prevent damage or accidental system trips.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746736353532,"sku":"DS200TCDAH1BHE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/DS200TCDAH1BHE.jpg?v=1773039116","url":"https:\/\/www.electronicplc.com\/products\/ge-ds200tcdah1bhe-digital-i-o-board","provider":"Electronic PLC","version":"1.0","type":"link"}