{"product_id":"ge-fanuc-ic670alg320-field-control-analog-output-module","title":"GE Fanuc IC670ALG320 Field Control Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC670ALG320 is a 4-channel analog output module designed for the Field Control I\/O system. This module converts digital control signals from a host processor into precise analog current or voltage outputs, facilitating the control of industrial actuators, regulating valves, dampers, and positioners. It is widely utilized in process automation environments, including power generation, oil and gas, and chemical manufacturing, where high-resolution signal stability is required.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour independent sourcing channels for current or voltage output.\u003c\/li\u003e\n\u003cli\u003eConfigurable output ranges: 0-20 mA, 4-20 mA, 0-10 VDC, and 0-12.5 VDC.\u003c\/li\u003e\n\u003cli\u003e12-bit digital-to-analog conversion resolution.\u003c\/li\u003e\n\u003cli\u003eIntegrated EMI filtering and ground isolation to protect signal integrity against electrical noise.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for monitoring field power and backplane bus status.\u003c\/li\u003e\n\u003cli\u003eConfigurable via external jumper links on the terminal block or internal register adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for applications requiring precise analog control, such as modulating control valves, variable frequency drive (VFD) speed references, and position control for industrial actuators. It is compatible with Field Control and Rx7i PACSystems architectures.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-10 VDC, 0-12.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e60 microseconds per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e20-29 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.4 W (min) to 4.3 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eUse instrumentation-grade shielded twisted-pair cabling to minimize susceptibility to electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC power supply is within the 20-29 VDC range and meets the ripple requirements.\u003c\/li\u003e\n\u003cli\u003eConfigure output ranges using the appropriate jumper settings on the terminal block assembly before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the enclosure to manage thermal dissipation, which can reach up to 4.3 Watts.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is installed in a clean, dry environment free from conductive dust and liquid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module compatible with all Field Control systems?\u003c\/h3\u003e\u003cp\u003eThe IC670ALG320 is designed for the Field Control I\/O series and is also compatible with specific Rx7i PACSystems architectures. Please verify your specific rack and Bus Interface Unit (BIU) compatibility before installation.\u003c\/p\u003e\u003ch3\u003eHow do I change the output range?\u003c\/h3\u003e\u003cp\u003eThe output range can be modified by adjusting the external jumper links located on the mounting terminal block assembly or by configuring the internal registers via a handheld programmer.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51000402280700,"sku":"IC670ALG320","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_2413ceb7-feaf-4ac6-940d-55f591ac25c5.jpg?v=1787250580","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-ic670alg320-field-control-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}