{"product_id":"ge-fanuc-ic694mdl655-pacsystems-rx3i-high-density-discrete-input-module","title":"General Electric IC694MDL655 PACSystems RX3i 32-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC694MDL655 is a high-density discrete input module designed for the PACSystems RX3i control platform. This module provides 32 points of discrete input, organized into four isolated groups of eight inputs each. It is engineered to interface with a wide range of field devices, supporting both positive and negative logic configurations to ensure flexibility in industrial control applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete input channels organized into 4 groups of 8.\u003c\/li\u003e\n\u003cli\u003eSupports both positive and negative logic input types.\u003c\/li\u003e\n\u003cli\u003eWide input voltage range compatibility (0-30 VDC nominal, up to 60 VDC).\u003c\/li\u003e\n\u003cli\u003eFast response time of 2 ms (maximum) for both On and Off transitions.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each channel to facilitate rapid diagnostics.\u003c\/li\u003e\n\u003cli\u003eOptical isolation between field side and backplane to protect control circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL655\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Groups\u003c\/td\u003e\n\u003ctd\u003e4 (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-30 VDC (Rated up to 60 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5 - 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 - 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7.0 mA per channel at rated voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e2 ms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e195 mA (max) from +5V bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e2 x 24-pin male connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PACSystems RX3i rack power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly into the RX3i backplane slot and secured using the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI interference, especially in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to prevent signal degradation and ensure compliance with maximum cable length specifications (30 meters).\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC694MDL655?\u003c\/h3\u003e\u003cp\u003eThe IC694MDL655 is a high-density discrete input module used to monitor the status of 32 field devices and communicate that state to the PACSystems RX3i PLC controller.\u003c\/p\u003e\u003ch3\u003eCan this module be used with both PNP and NPN sensors?\u003c\/h3\u003e\u003cp\u003eYes, the module supports both positive and negative logic, allowing it to interface with a variety of standard industrial sensors and switches.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum cable length for inputs?\u003c\/h3\u003e\u003cp\u003eThe recommended maximum cable length for field inputs connected to this module is 30 meters to ensure signal integrity and proper response times.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50644544782588,"sku":"IC694MDL655","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bb0d372d-ea13-457e-aa6f-ab52475d7c87.jpg?v=1784967279","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-ic694mdl655-pacsystems-rx3i-high-density-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}