{"product_id":"ge-fanuc-ic697mdl671-series-90-70-input-module","title":"GE Fanuc IC697MDL671 Series 90-70 16-Point 24 VDC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC697MDL671 is a high-density 16-point DC input module designed for integration within the Series 90-70 PLC platform. This module serves as a reliable interface for 24 VDC field devices, enabling precise signal sensing in complex industrial automation systems, including power generation, chemical processing, and manufacturing facilities. By incorporating robust galvanic isolation, the module protects the PLC processor from voltage transients and ground loops, ensuring high signal integrity and reducing the risk of false triggering in electrically noisy environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete input points for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eOptimized for 24 VDC field device compatibility.\u003c\/li\u003e\n\u003cli\u003eIntegrated 1500 V isolation between field-side inputs and the logic backplane.\u003c\/li\u003e\n\u003cli\u003eSupports both positive and negative polarity input configurations.\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient operation with low backplane power consumption.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard rack-based deployment in Series 90-70 systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for a wide range of industrial control applications where discrete 24 VDC sensing is required. It is commonly utilized in large-scale process control systems, automated assembly lines, and critical infrastructure monitoring where system stability and signal accuracy are paramount.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697MDL671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-3 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state Voltage\u003c\/td\u003e\n\u003ctd\u003e13.5 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state Voltage\u003c\/td\u003e\n\u003ctd\u003e-3 to 5 VDC (Positive), -5 to 30 VDC (Negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-state Current\u003c\/td\u003e\n\u003ctd\u003e6 to 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-state Current\u003c\/td\u003e\n\u003ctd\u003e0 to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the backplane slot to ensure reliable electrical contact.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the PLC rack to ensure the effectiveness of the module's isolation.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the cabinet to maintain the operating temperature within the 0 to 60 degC range.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) precautions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC697MDL671?\u003c\/strong\u003e\u003cbr\u003eThe IC697MDL671 is a discrete input module used to interface 24 VDC field signals with a GE Fanuc Series 90-70 PLC system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support both positive and negative logic?\u003c\/strong\u003e\u003cbr\u003eYes, the module is designed to handle both positive and negative voltage polarities within the specified OFF-state and ON-state thresholds.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the isolation rating of this module?\u003c\/strong\u003e\u003cbr\u003eThe module provides 1500 V of isolation between the field inputs and the logic-side backplane to protect the CPU from electrical transients.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51020227248380,"sku":"IC697MDL671","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d13c27c0-9aa7-45d2-8134-17d2df898383.jpg?v=1787849833","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-ic697mdl671-series-90-70-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}