{"product_id":"ge-fanuc-series-90-30-ic693alg390-analog-output-module","title":"General Electric IC693ALG390 90-30 Series Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC693ALG390 is a high-performance analog output module designed for the General Electric Series 90-30 Programmable Logic Controller (PLC) system. This module provides two independent output channels capable of delivering precise voltage signals in the range of -10 to +10 VDC. It is engineered for demanding industrial environments, facilitating closed-loop control, signal transmission to measuring instruments, and integration with data logging systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo isolated analog output channels (-10 to +10 VDC).\u003c\/li\u003e\n\u003cli\u003eHigh resolution of 2.5 mV per count.\u003c\/li\u003e\n\u003cli\u003eAbsolute accuracy of ± 5 mV at 25 degC.\u003c\/li\u003e\n\u003cli\u003e1500 VDC isolation between field wiring and PLC logic circuitry.\u003c\/li\u003e\n\u003cli\u003eFast 5 ms update rate.\u003c\/li\u003e\n\u003cli\u003eSupports hold-last-state or 0V default configuration.\u003c\/li\u003e\n\u003cli\u003eExternal 24 VDC power supply input for standby operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically utilized in process control applications where precise voltage-based control is required, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eClosed-loop process control systems.\u003c\/li\u003e\n\u003cli\u003eDriving analog actuators and valves.\u003c\/li\u003e\n\u003cli\u003eInterfacing with chart recorders and data acquisition systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation test benches.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693ALG390\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e2.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 5 mV at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC (Field to Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e2000 pF maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect power from the PLC rack before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is fully seated in the 90-30 baseplate slot and secured with the integrated locking screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for analog signals to minimize EMI interference. Ensure the shield is grounded at the source end only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e The module provides 1500V isolation; however, ensure external field wiring is routed away from high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain ambient operating temperatures between 0 and 60 degC. Ensure adequate ventilation within the enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC693ALG390?\u003c\/h3\u003e\u003cp\u003eThe GE IC693ALG390 is a 2-channel, isolated analog voltage output module for the Series 90-30 PLC system.\u003c\/p\u003e\u003ch3\u003eWhat is the voltage output range?\u003c\/h3\u003e\u003cp\u003eIt provides a bipolar voltage output range of -10 to +10 VDC.\u003c\/p\u003e\u003ch3\u003eDoes this module support current output?\u003c\/h3\u003e\u003cp\u003eNo, this module is strictly for voltage output. For current output applications (e.g., 4-20mA), please refer to alternative modules such as the IC693ALG391 or IC693ALG392.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50646404563196,"sku":"IC693ALG390","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_97bc0ee8-dd05-46e4-8691-af5d86e67327.jpg?v=1785031018","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-series-90-30-ic693alg390-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}