{"product_id":"ge-fanuc-series-one-ic610mdl107-input-module","title":"GE Fanuc IC610MDL107 Series One 16-Point 24 VDC Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC610MDL107 is a high-density discrete input module designed for the Series One programmable logic controller (PLC) platform. This module provides 16 isolated sink-type input points, allowing for the integration of 24 VDC field devices such as sensors, limit switches, and pushbuttons into the control system. It is engineered to provide reliable signal conditioning and real-time status monitoring, making it a critical component for maintaining precise automation sequencing in legacy industrial control environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete sink input channels for 24 VDC field devices.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each input point to facilitate rapid field-side troubleshooting.\u003c\/li\u003e\n\u003cli\u003eRemovable terminal block design allows for module replacement without disturbing field wiring.\u003c\/li\u003e\n\u003cli\u003eOptimized for low power consumption from the PLC backplane.\u003c\/li\u003e\n\u003cli\u003eRobust signal isolation to mitigate the impact of electrical noise on control logic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in legacy industrial automation systems, including water treatment facilities, material handling systems, and general manufacturing process control where space-efficient, high-density I\/O is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries One\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Input Current\u003c\/td\u003e\n\u003ctd\u003e17 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Draw\u003c\/td\u003e\n\u003ctd\u003e25 mA at 9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC backplane power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the module securely in the Series One rack to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI interference in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the sink input configuration matches the sourcing output of field devices.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the PLC rack to maintain operating temperatures within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IC610MDL107 compatible with modern PLC systems?\u003c\/h3\u003e\u003cp\u003eThe IC610MDL107 is specifically designed for the legacy GE Fanuc Series One platform. It is not natively compatible with modern PLC systems unless used as part of a legacy migration or bridge solution.\u003c\/p\u003e\u003ch3\u003eCan I replace the module without rewiring?\u003c\/h3\u003e\u003cp\u003eYes, the module features a removable terminal block. You can unseat the terminal block from the old module and attach it to the new unit, provided the wiring remains intact and the replacement module is identical.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50912082166012,"sku":"IC610MDL107","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c73ca1c8-4a7f-441e-aec6-7b82a3528fc3.jpg?v=1785725714","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-series-one-ic610mdl107-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}