{"product_id":"ge-fanuc-series-one-ic610mdl125-input-module","title":"GE Fanuc Series One IC610MDL125 8-Point 115 VAC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe IC610MDL125 is a high-reliability digital input module designed for the GE Fanuc Series One programmable logic controller (PLC) system. This 8-point module is engineered to interface with 115 VAC field devices, providing robust data acquisition for industrial applications such as material handling, discrete manufacturing, and assembly automation. By converting AC field signals into clean digital inputs for the PLC, the module ensures consistent system response times and reliable signal processing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8 independent input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each channel to facilitate real-time diagnostics and visual troubleshooting.\u003c\/li\u003e\n\u003cli\u003eCalibrated input impedance of 9.5K Ohms to maintain signal integrity and provide isolation from field-level power fluctuations.\u003c\/li\u003e\n\u003cli\u003eOptimized for low-power consumption, drawing only 10 mA at 9 VDC.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration with Series One base units and I\/O racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis module is ideal for industrial environments requiring reliable AC signal detection, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiscrete manufacturing control systems.\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor automation.\u003c\/li\u003e\n\u003cli\u003eAssembly line monitoring and sequencing.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose PLC-based AC signal acquisition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries One\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAC Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e97 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e9.5K Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 mA at 9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e1 Unit at 9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the PLC power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the Series One base unit slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring is properly secured to the terminal blocks and that shielded cables are used where necessary to minimize EMI.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module for proper ventilation and heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC610MDL125?\u003c\/strong\u003e\u003cbr\u003eThis module acts as an interface between 115 VAC field devices and the GE Fanuc Series One PLC, converting AC signals into digital logic levels for the processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the inputs?\u003c\/strong\u003e\u003cbr\u003eThe module is designed to interface with 115 VAC field signals; the internal logic power is derived from the PLC backplane (9 VDC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify if an input is active?\u003c\/strong\u003e\u003cbr\u003eThe module features 8 integrated LED indicators on the front panel, which illuminate when the corresponding input channel is energized.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50919529873660,"sku":"IC610MDL125","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_e6d299ba-d93b-43c5-931b-abbdd27b2282.jpg?v=1785903587","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-series-one-ic610mdl125-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}