{"product_id":"ge-fanuc-versamax-ic693alg392-analog-output-module","title":"General Electric IC693ALG392 Series 90-30 Analog Current\/Voltage Output Module","description":"\u003cp\u003eThe General Electric IC693ALG392 is a high-performance analog output module designed for the Series 90-30 PLC platform. This module provides eight single-ended output channels capable of delivering both voltage and current signals, making it suitable for a wide range of industrial control applications requiring precise analog signal generation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight (8) single-ended analog output channels.\u003c\/li\u003e\n\u003cli\u003eConfigurable output ranges: 0 to 10 V, -10 to 10 V, 0 to 20 mA, and 4 to 20 mA.\u003c\/li\u003e\n\u003cli\u003eConfigurable resolution of 15 or 16 bits depending on the selected range.\u003c\/li\u003e\n\u003cli\u003eFast update rate of 8 ms for all channels.\u003c\/li\u003e\n\u003cli\u003eRequires external 24 VDC power supply for analog signal generation.\u003c\/li\u003e\n\u003cli\u003eCompatible with Series 90-30 and PACSystems RX3i I\/O racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWater and wastewater treatment systems.\u003c\/li\u003e\n\u003cli\u003eManufacturing and assembly line automation.\u003c\/li\u003e\n\u003cli\u003ePower distribution and monitoring.\u003c\/li\u003e\n\u003cli\u003eGeneral process industry control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693ALG392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, -10 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e8 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e20 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power\u003c\/td\u003e\n\u003ctd\u003e5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Voltage)\u003c\/td\u003e\n\u003ctd\u003e0.3125 mV per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (4-20 mA)\u003c\/td\u003e\n\u003ctd\u003e0.5 microamps per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (0-20 mA)\u003c\/td\u003e\n\u003ctd\u003e0.625 microamps per count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be installed in a standard Series 90-30 or RX3i I\/O slot.\u003c\/li\u003e\n\u003cli\u003eConnect an isolated 24 VDC power source to the module's terminal block to enable analog signal output.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the cable shields at the signal source or PLC end according to local electrical codes.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to ensure proper ventilation and cooling within the enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC693ALG392?\u003c\/h3\u003e\u003cp\u003eThe IC693ALG392 is an 8-channel analog current\/voltage output module from the GE Fanuc Series 90-30 PLC family, designed to convert digital values into precise analog signals for field devices.\u003c\/p\u003e\u003ch3\u003eWhat are the power requirements?\u003c\/h3\u003e\u003cp\u003eThe module draws 5 VDC from the PLC backplane and requires a user-supplied 24 VDC external power source (20-30 VDC range) connected to the terminal block for output signal generation.\u003c\/p\u003e\u003ch3\u003eWhere can this module be installed?\u003c\/h3\u003e\u003cp\u003eIt can be installed in any available I\/O slot of a Series 90-30 or PACSystems RX3i rack system.\u003c\/p\u003e\u003ch3\u003eHow do I test the module?\u003c\/h3\u003e\u003cp\u003eYou can verify functionality by using a calibrated multimeter on the output terminals. By commanding specific counts (e.g., 0 to 32,000) from the PLC, you can measure the corresponding proportional voltage or current output.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50974977917180,"sku":"IC693ALG392","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_07d2b8c5-c32a-4fc3-8c3b-7602c0ec3727.jpg?v=1786638879","url":"https:\/\/www.electronicplc.com\/products\/ge-fanuc-versamax-ic693alg392-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}