{"product_id":"general-electric-versamax-ic200ebi001-ethernet-slave-module","title":"General Electric IC200EBI001 VersaMax Ethernet Network Interface Unit","description":"\u003cp\u003eThe IC200EBI001 is a VersaMax Ethernet Network Interface Unit (ENIU) designed to facilitate distributed I\/O architecture within industrial control systems. This module acts as an Ethernet slave, managing communication between the host controller and local I\/O modules. It supports standard Ethernet connectivity, allowing for integration into various automation networks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eServes as a high-performance Network Interface Unit (NIU) for the VersaMax I\/O family.\u003c\/li\u003e\n\u003cli\u003eSupports 10\/100 Mbps Ethernet communication with auto-negotiation.\u003c\/li\u003e\n\u003cli\u003eConfigurable via rotary switches (X1, X10, X100) for IP address assignment or via ARP commands.\u003c\/li\u003e\n\u003cli\u003eSupports up to 1024 bytes of total I\/O data (512 bytes input \/ 512 bytes output).\u003c\/li\u003e\n\u003cli\u003eScalable architecture: Supports up to 8 modules (Release 1.0) or up to 64 modules with 7 expansion racks (Release 1.1 and later).\u003c\/li\u003e\n\u003cli\u003eIntegrated LED diagnostics for PWR, OK, FAULTS, LAN, and STAT status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWater treatment and municipal wastewater management systems.\u003c\/li\u003e\n\u003cli\u003eOil and gas production, refining, and distribution automation.\u003c\/li\u003e\n\u003cli\u003ePower and energy management, including generator and transformer monitoring.\u003c\/li\u003e\n\u003cli\u003eIntelligent machinery manufacturing and industrial furnace control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200EBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps (Auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Media\u003c\/td\u003e\n\u003ctd\u003eEthernet Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Drop Length\u003c\/td\u003e\n\u003ctd\u003e100 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 64 modules (firmware dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003ePWR, OK, FAULTS, LAN, STAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMount the unit on a 35mm x 7.5mm conductive, unpainted DIN rail to ensure proper chassis grounding.\u003c\/li\u003e\n\u003cli\u003eEnsure the side connector cover remains in place on the last carrier to protect internal pins from ESD and physical damage.\u003c\/li\u003e\n\u003cli\u003eVerify the power supply locking latch is in the \"locked\" position during operation to prevent intermittent power loss.\u003c\/li\u003e\n\u003cli\u003eMaintain recommended environmental clearances around the module to prevent overheating and ensure rated thermal performance.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing I\/O modules to prevent electrical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200EBI001?\u003c\/h3\u003e\u003cp\u003eThe IC200EBI001 is an Ethernet Network Interface Unit that allows VersaMax I\/O modules to communicate over an Ethernet network, enabling distributed I\/O control.\u003c\/p\u003e\u003ch3\u003eHow is the IP address configured?\u003c\/h3\u003e\u003cp\u003eThe module features three rotary switches (X1, X10, X100) for manual IP address assignment. Alternatively, the IP address can be configured via the DOS command prompt using the arp-s command.\u003c\/p\u003e\u003ch3\u003eDoes the module support auto-configuration?\u003c\/h3\u003e\u003cp\u003eYes, the module performs an auto-configuration sequence upon power-up, identifying connected I\/O modules until an empty slot or fault is detected.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50980437098748,"sku":"IC200EBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_597535fd-4c7c-4b99-9097-3918106c3e57.jpg?v=1786724651","url":"https:\/\/www.electronicplc.com\/products\/general-electric-versamax-ic200ebi001-ethernet-slave-module","provider":"Electronic PLC","version":"1.0","type":"link"}