{"product_id":"genset-controller-woodward-8440-2050-easygen-3200-5-p1","title":"Genset Controller Woodward 8440-2050 EasyGen-3200-5\/P1","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 8440-2050\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8440-2050\u003c\/strong\u003e Genset Controller, operates as a dedicated hardware component for complex generator management and breaker synchronizing control within EasyGen-3200-5\/P1 power distribution networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 cm x 13 cm x 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range (-20 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Operating Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-Model \/ Package\u003c\/td\u003e\n\u003ctd\u003eEasyGen-3200-5\/P1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEasyGen-3000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003eMulti-Unit Genset Power Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response \u0026amp; Governor Control\u003c\/h3\u003e\n\u003cp\u003eThe controller processes engine speed and voltage sensing loops to deliver precise frequency and voltage regulation output commands. Actuator loop feedback response directly determines dynamic load-sharing stability across multiple paralleled generators, adjusting fuel governor biasing dynamically to absorb step-load transients. Integrated active power control circuitry prevents steady-state hunting and reduces electrical stress during automated breaker synchronization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: How should communication cables for CAN and RS-485 interfaces be grounded?\u003c\/li\u003e\n\u003cli\u003eA: Communication bus lines require twisted-pair shielded cabling, with drain wires grounded at a single chassis ground point to avoid creating ground loop currents.\u003c\/li\u003e\n\u003cli\u003eQ: What cable separation rules apply when installing this control unit in switchgear cabinets?\u003c\/li\u003e\n\u003cli\u003eA: Sensor signal wires, magnetic pickup cables, and network communications must run in separate wireways away from high-current AC power leads and inductive switching coils.\u003c\/li\u003e\n\u003cli\u003eQ: What mechanism provides primary thermal management during continuous operation?\u003c\/li\u003e\n\u003cli\u003eA: Heat dissipation occurs through conduction and natural convection across the metal housing; adequate clearance must be provided around the unit inside the cabinet enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller securely using hardware torque limits specified for the front panel or chassis cutout.\u003c\/li\u003e\n\u003cli\u003eRoute auxiliary DC supply power through dedicated overcurrent protection prior to energizing the main terminal blocks.\u003c\/li\u003e\n\u003cli\u003eVerify proper phasing and line-to-line AC voltage sensing connections before initiating system commissioning tests.\u003c\/li\u003e\n\u003cli\u003eGround the control chassis to the main switchgear earth busbar using a short, low-impedance grounding strap.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50738598904060,"sku":"8440-2050 EASYGEN-3200-5\/P1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-2050_EASYGEN-3200-5P11.jpg?v=1785376955","url":"https:\/\/www.electronicplc.com\/products\/genset-controller-woodward-8440-2050-easygen-3200-5-p1","provider":"Electronic PLC","version":"1.0","type":"link"}