{"product_id":"he693rtd600-ge-fanuc-plc-i-o-rtd-input-module","title":"General Electric HE693RTD600 90-30 Series 6-Channel RTD Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe HE693RTD600 is a high-precision 6-channel Resistance Temperature Device (RTD) input module designed for the GE Fanuc Series 90-30 PLC platform. This module enables direct connection of various RTD sensors, providing reliable temperature data acquisition without the need for external signal conditioning. It features 16-bit A\/D conversion and robust fault protection, making it suitable for demanding industrial temperature monitoring applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e6-channel RTD input support for flexible sensor integration.\u003c\/li\u003e\n\u003cli\u003e16-bit integrating A\/D conversion for high-resolution data.\u003c\/li\u003e\n\u003cli\u003eFault protection via Zener diode clamp for enhanced reliability.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance (\u0026gt;1000 Meg Ohm) ensuring superior signal integrity.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time status monitoring and fault identification.\u003c\/li\u003e\n\u003cli\u003eBuilt-in diagnostics for internal health checks and signal irregularity detection.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of RTD types including PT-100, Ni-120, Cu-10, and linear resistors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHE693RTD600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.5 degC or 0.5 degF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5 degC typical (+\/- 1.0 degC for Cu-10 and TD5R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e50 channels per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1000 Meg Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eInstall the module in an available slot within the Series 90-30 baseplate.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RTD connections to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of cable shields at the module terminal block or designated ground point.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is configured correctly in the PLC software, specifically setting the %AI size to 6.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the PLC rack to ensure the ambient temperature remains within the 0 to 60 degC operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the HE693RTD600?\u003c\/h3\u003e\u003cp\u003eIt is a 6-channel RTD input module designed for the GE Fanuc Series 90-30 PLC, allowing direct connection of RTD sensors for temperature monitoring.\u003c\/p\u003e\u003ch3\u003eWhat types of sensors does HE693RTD600 support?\u003c\/h3\u003e\u003cp\u003eThe module supports various sensors including PT-90, PT-100 (multiple alpha values), Ni-120, Cu-10, Cu-50, Cu-53, Cu-100, Pt-1000, TD5R, and linear resistors.\u003c\/p\u003e\u003ch3\u003eWhat are the power requirements?\u003c\/h3\u003e\u003cp\u003eThe module consumes 75 mA at 5 VDC from the PLC backplane.\u003c\/p\u003e\u003ch3\u003eHow is the module configured?\u003c\/h3\u003e\u003cp\u003eConfiguration is performed via the PLC software, requiring the setting of five parameters, including the %AI size (set to 6) and specific byte configurations as outlined in the technical manual.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50953267511548,"sku":"HE693RTD600","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_35d1d346-d002-42d9-b9ef-081430a65cbd.jpg?v=1786238123","url":"https:\/\/www.electronicplc.com\/products\/he693rtd600-ge-fanuc-plc-i-o-rtd-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}