{"product_id":"high-density-ac-output-140dao85300-for-modicon-quantum-plc","title":"High-Density AC Output 140DAO85300 for Modicon Quantum PLC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric 140DAO85300 functions as a high-density AC output interface for the Modicon Quantum automation platform. This module provides 32 discrete AC channels, allowing the PLC to control high-voltage loads such as motor starters, solenoid valves, and large relay banks. It operates across a wide voltage spectrum (20 to 253 V AC), making it a versatile choice for global industrial power standards. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance in mission-critical control architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 140DAO85300 combines high current capacity with robust electrical protection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels (4 Isolated Groups of 8)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 to 253 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e47 to 63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A rms per point \/ 16 A rms per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 0.5 ms (ON\/OFF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 V maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 2.5 A for 1 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal 4 A Fuse per group and RC Filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e320 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50-Pin SUB-D Female (CableFast Compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE, UL 508, CSA C22.2 No.142, FM Class 1 Div 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 140DAO85300 addresses the specific rigors of heavy industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Power Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a total module capacity of 16 A rms, this module drives multiple high-power loads simultaneously without requiring external interposing relays for standard AC actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransient Interference Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RC filters dampen electrical noise and voltage spikes. This prevents transient events from causing false triggers or damaging sensitive internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front panel features 32 green status LEDs for real-time channel monitoring. A dedicated red fault LED immediately signals fuse failure or internal malfunctions, accelerating the troubleshooting process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact High-Density Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe use of a 50-pin SUB-D connector enables the use of CableFast terminal blocks. This reduces cabinet wiring time and minimizes the risk of terminal connection errors in crowded control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle different AC frequencies?\u003c\/strong\u003eYes, the 140DAO85300 supports a frequency range from 47 to 63 Hz, ensuring compatibility with both 50Hz and 60Hz power grids worldwide.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a group exceeds the 4 A current limit?\u003c\/strong\u003eThe module contains an internal 4 A fuse for each group. If the load exceeds this threshold, the fuse blows to protect the module circuitry, and the red \"Fault\" LED illuminates to alert the operator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs it possible to mix different AC voltages across groups?\u003c\/strong\u003eYes. Since the module organizes the 32 channels into four isolated groups of eight, you can apply different AC voltage sources to each group as long as they stay within the 20 to 253 V AC range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support DC loads?\u003c\/strong\u003eNo. The 140DAO85300 uses Triac-based switching designed specifically for AC current. Attempting to switch DC loads will result in the output failing to turn off once energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":49073892294908,"sku":"140DAO85300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/4._4baec79f-e0d3-49f2-8a8d-622d91780f0f.jpg?v=1778140819","url":"https:\/\/www.electronicplc.com\/products\/high-density-ac-output-140dao85300-for-modicon-quantum-plc","provider":"Electronic PLC","version":"1.0","type":"link"}