{"product_id":"honeywell-cc-pui001-51454205-175-universal-i-o-module","title":"Honeywell CC-PUI001 51454205-175 Universal I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PUI001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51454205-175\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esoftware-configurable interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion Series 8 I\/O systems\u003c\/strong\u003e. This module integrates various signal types—\u003cstrong\u003eanalog input\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog output\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital input\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital output\u003c\/strong\u003e—into a single high-density platform. With per-channel configuration, it eliminates the need for separate modules, reducing spare parts and cabinet space. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor maximum system availability in critical process control networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-PUI001  51454205-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Channels per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V (Analog), 24V DC (Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated HART support on all analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.9 x 21.6 x 6.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Defined Channels\u003c\/strong\u003e: Configure each of the 32 channels individually for a mix of transmitters, valves, and switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Diagnostics\u003c\/strong\u003e: Extracts digital calibration and health data from field instruments, enabling predictive maintenance without external multiplexers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFootprint Optimization\u003c\/strong\u003e: 32-channel design reduces I\/O module requirements, freeing up space for future expansions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Error Isolation\u003c\/strong\u003e: Independent circuitry for each channel prevents faults from affecting adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring\u003c\/strong\u003e: Universal I\/O standardization ensures consistent wiring patterns for all signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eDoes the CC-PUI001 support redundant configurations?\u003c\/h4\u003e\n\u003cp\u003eYes, it can be installed in a redundant pair on a Series 8 IOTA. The secondary module provides seamless failover without interrupting signals.\u003c\/p\u003e\n\u003ch4\u003eCan I mix analog and digital signals on the same module?\u003c\/h4\u003e\n\u003cp\u003eYes, the CC-PUI001 allows full signal mixing. You can configure channels as analog or digital as needed.\u003c\/p\u003e\n\u003ch4\u003eIs this module compatible with Series C IOTA bases?\u003c\/h4\u003e\n\u003cp\u003eNo, it is compatible only with Series 8 IOTAs for proper connection.\u003c\/p\u003e\n\u003ch4\u003eHow does the module handle power-limited field devices?\u003c\/h4\u003e\n\u003cp\u003eIt includes current-limiting protection for each channel to prevent damage from wiring faults and maintain loop integrity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901027758332,"sku":"CC-PUI001 51454205-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-PUI001_51454205-1751.jpg?v=1774857422","url":"https:\/\/www.electronicplc.com\/products\/honeywell-cc-pui001-51454205-175-universal-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}