{"product_id":"honeywell-cc-taox11-51308353-175-experion-pks-analog-output-module","title":"Honeywell CC-TAOX11 51308353-175 Experion PKS Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-TAOX11 (Part Number 51308353-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance analog output component within the Experion PKS Series C I\/O family. This module regulates precise current or voltage signals to control field actuators, positioners, and variable speed drives. It operates as a vital link in the control loop, translating digital processor commands into physical action at the process level. This unit is supplied in 100% brand new and original factory condition to ensure peak system performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51308353-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e170 x 100 x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output (AO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeries C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New and Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Dissipation\u003c\/strong\u003e: The slim 40 mm profile enhances airflow within high-density I\/O cabinets, reducing heat accumulation and extending component lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced EMI Shielding\u003c\/strong\u003e: Internal grounding and shielding structures minimize electromagnetic interference, ensuring stable and accurate signal output in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid DIN Rail Integration\u003c\/strong\u003e: Designed for standard 35 mm DIN rail mounting, enabling quick installation and efficient control panel layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Control Resolution\u003c\/strong\u003e: High-resolution digital-to-analog conversion reduces signal jitter, supporting fine control of valves, actuators, and dosing systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eDoes the CC-TAOX11 require a specific I\/O Termination Assembly (IOTA)?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed with a compatible Series C IOTA. The selected IOTA should match the system’s redundancy, wiring, and loop requirements within the Experion PKS rack.\u003c\/p\u003e\n\u003ch4\u003eWhat differentiates the CC-TAOX11 from standard AO modules?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers improved diagnostics and a compact form factor (0.4 kg), enabling higher I\/O density and more efficient cabinet utilization compared to earlier-generation Honeywell modules.\u003c\/p\u003e\n\u003ch4\u003eCan I swap this module while the system is under power?\u003c\/h4\u003e\n\u003cp\u003eYes, the Series C architecture supports hot-swapping, allowing the module to be replaced without shutting down the controller or interrupting communication with other modules.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48901049614588,"sku":"CC-TAOX11 51308353-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-TAOX11_51308353-1752.jpg?v=1774854174","url":"https:\/\/www.electronicplc.com\/products\/honeywell-cc-taox11-51308353-175-experion-pks-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}