{"product_id":"honeywell-fs-sdo-824-safe-digital-output-module","title":"Honeywell FS-SDO-824 Safe Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FS-SDO-824 is a high-integrity 8-channel digital output module designed for Honeywell Safety Manager and Fail-Safe Control (FSC) systems. It provides safe and reliable control of critical field actuators such as solenoid valves, motor starters, and indicator lamps. Supplied as 100% brand new and original, this module ensures dependable performance for safety-instrumented functions (SIF) in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFS-SDO-824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC solid-state source (short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 25 mA24 VDC Internal: 25 mA24 VDC External: 70 mA (no load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lamp Load\u003c\/td\u003e\n\u003ctd\u003e120 mA (2.9 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.0 VDC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWDG Input Current\u003c\/td\u003e\n\u003ctd\u003e8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eActive Short-Circuit Protection\u003c\/strong\u003e\u003cbr\u003eReal-time current monitoring isolates any faulted channel instantly, protecting both the module and system from damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Watchdog (WDG) Interface\u003c\/strong\u003e\u003cbr\u003eEnsures outputs automatically revert to a safe-off state if communication with the central processor is lost.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Low Leakage Current\u003c\/strong\u003e\u003cbr\u003eOff-state leakage below 0.1 mA prevents unintended activation of sensitive field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Drive Capability\u003c\/strong\u003e\u003cbr\u003eSupports up to 550 mA per channel, enabling direct control of industrial solenoids and relay coils without additional relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic System Isolation\u003c\/strong\u003e\u003cbr\u003eSeparates logic and field power domains, protecting the safety processor from electrical transients and inductive disturbances.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between FS-SDO-824 and FC-SDO-824?\u003c\/strong\u003e\u003cbr\u003eThe FS version is non-conformal coated for standard environments, while the FC version includes protective coating for high-humidity or corrosive conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it drive LED indicators?\u003c\/strong\u003e\u003cbr\u003eYes. It supports lamp loads up to 120 mA, suitable for LED indicators and signaling devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require external 24VDC power?\u003c\/strong\u003e\u003cbr\u003eYes. External 24 VDC is required to power field-side loads, while internal supplies handle module logic and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify it is 100% brand new?\u003c\/strong\u003e\u003cbr\u003eEach unit is delivered in original Honeywell packaging with security seals, serial numbers, and manufacturing date codes for full authenticity verification.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48969396551932,"sku":"FS-SDO-824","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FS-SDO-8242.jpg?v=1776146824","url":"https:\/\/www.electronicplc.com\/products\/honeywell-fs-sdo-824-safe-digital-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}