{"product_id":"honeywell-honeywell-safety-systems-fs-tsgas-1624-digital-input-field-termination-assembly","title":"Honeywell FS-TSGAS-1624 Safety Systems Gas and Flame Detector Input Field Termination Assembly","description":"\u003cp\u003eThe Honeywell FS-TSGAS-1624 is a 16-channel Fail-Safe Gas and Flame Detector Input Field Termination Assembly (FTA) designed for integration with Honeywell Safety Manager safety instrumented systems. This module serves as a critical interface between field-mounted gas detectors, flame detectors, and the SAI-1620m safe analog input module, ensuring reliable signal acquisition for safety-critical applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel analog input interface for gas and flame detectors.\u003c\/li\u003e\n\u003cli\u003eSupports standard 0–20 mA and 4–20 mA input signals.\u003c\/li\u003e\n\u003cli\u003eProvides linear conversion of field signals to levels required by the SAI-1620m module.\u003c\/li\u003e\n\u003cli\u003eIntegrated per-channel 500 mAT fuse for transmitter power protection.\u003c\/li\u003e\n\u003cli\u003eSupports HART communication for advanced diagnostic and configuration capabilities.\u003c\/li\u003e\n\u003cli\u003eUniversal snap-in mounting for standard DIN EN rails.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD): Triggers facility shutdown upon detection of hazardous gas or flame conditions.\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) Systems: Provides a robust input interface for combustible\/toxic gas and flame monitoring sensors.\u003c\/li\u003e\n\u003cli\u003eCritical Process Protection: Processes 0-20 mA safety signals within the Honeywell Safety Manager architecture.\u003c\/li\u003e\n\u003cli\u003eTurbomachinery: Supports control and protection loops for large-scale turbines and compressors.\u003c\/li\u003e\n\u003cli\u003ePipeline Infrastructure: Facilitates leak monitoring across extensive industrial pipeline networks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eFS-TSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 Ohm (± 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0–4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e500 mAT (per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating (AC)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating (DC)\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMount the FTA securely on standard DIN EN rails (TS32 or TS35 x 7.5).\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum rail length of 226 mm to accommodate the module footprint.\u003c\/li\u003e\n\u003cli\u003eUse the dedicated terminal on each channel for field cable shield termination to minimize EMI.\u003c\/li\u003e\n\u003cli\u003eVerify power supply polarity and connections before energizing the system.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the cabinet to maintain operating temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the FS-TSGAS-1624?\u003c\/h3\u003e\u003cp\u003eIt acts as a 16-channel interface that converts 0(4)-20 mA analog field signals from gas and flame detectors into the signal levels required by the SAI-1620m high-density analog input module.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with HART communication?\u003c\/h3\u003e\u003cp\u003eYes, the module supports HART communication, allowing for advanced device diagnostics and configuration of connected field instruments.\u003c\/p\u003e\u003ch3\u003eHow are the field transmitters protected?\u003c\/h3\u003e\u003cp\u003eEach analog input channel is equipped with an individual 500 mAT fuse to protect the power supply to the field transmitter.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50986101506300,"sku":"FS-TSGAS-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_381c6482-2036-42f9-b796-f595896ce567.jpg?v=1786816818","url":"https:\/\/www.electronicplc.com\/products\/honeywell-honeywell-safety-systems-fs-tsgas-1624-digital-input-field-termination-assembly","provider":"Electronic PLC","version":"1.0","type":"link"}