{"product_id":"honeywell-mc-taih03-analog-input-fta","title":"Honeywell MC-TAIH03 Analog Input FTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell MC-TAIH03 is a high-level analog input Field Termination Assembly (FTA) engineered to facilitate the interface between field instrumentation and Honeywell distributed control systems. This module serves as a centralized termination point for up to 16 analog input channels, streamlining the connection process between field sensors and control system I\/O hardware. By providing a structured interface, the MC-TAIH03 reduces field wiring complexity, minimizes potential installation errors, and enhances overall system maintainability in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports 16 high-level analog input channels.\u003c\/li\u003e\n\u003cli\u003eConsolidates field wiring to improve diagnostic efficiency and system reliability.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration with Honeywell distributed control system architectures.\u003c\/li\u003e\n\u003cli\u003eProvides a robust interface for signal routing under typical industrial electrical noise conditions.\u003c\/li\u003e\n\u003cli\u003ePassive design requiring no internal active power consumption.\u003c\/li\u003e\n\u003cli\u003eCE marked for compliance with industrial safety and electromagnetic compatibility standards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MC-TAIH03 is widely utilized in large-scale process industries, including refinery automation, power generation plants, chemical processing units, and heavy industrial monitoring systems where stable, high-integrity analog signal acquisition is required for process control.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eHigh-level analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCabinet or rack mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing the FTA module.\u003c\/li\u003e\n\u003cli\u003eMount the assembly securely within the designated control cabinet or rack space, ensuring adequate clearance for cable routing.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field instrumentation to maintain signal integrity and minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify all screw terminal connections are tightened to the specified torque to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the cabinet and signal shields to ensure compliance with system-level electrical isolation requirements.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation environment remains within the specified temperature and humidity ranges to prevent component degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the MC-TAIH03?\u003c\/h3\u003e\u003cp\u003eThe MC-TAIH03 acts as a field termination assembly that aggregates 16 analog input signals from field devices and routes them to the control system I\/O modules, simplifying wiring and maintenance.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eNo, the MC-TAIH03 is a passive field termination assembly and does not consume internal power.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all Honeywell systems?\u003c\/h3\u003e\u003cp\u003eThe MC-TAIH03 is designed for specific Honeywell distributed control system architectures. Please verify your system's hardware compatibility documentation before installation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50734180335868,"sku":"MC-TAIH03","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3f7b351e-2649-448a-bdb7-34589d1fe053.jpg?v=1785301126","url":"https:\/\/www.electronicplc.com\/products\/honeywell-mc-taih03-analog-input-fta","provider":"Electronic PLC","version":"1.0","type":"link"}