{"product_id":"ic200chs001-ge-fanuc-versamax-barrier-style-i-o-carrier","title":"IC200CHS001 GE Fanuc VersaMax Barrier-Style I\/O Carrier","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS001 (IC200-CHS-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style wiring base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax I\/O platform\u003c\/strong\u003e. It provides a rugged mechanical and electrical interface between field devices and I\/O modules, featuring an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen barrier-strip design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy access to termination points. The carrier supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping of modules\u003c\/strong\u003e, integrated mechanical keying to prevent incorrect installation, and accommodates both AC and DC signals, making it suitable for demanding industrial environments with high vibration or heavy-duty wiring requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBarrier-Style Screw Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0–264 VAC (Operational)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Protection\u003c\/td\u003e\n\u003ctd\u003eUp to 300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per signal point \/ 8 A per power\/ground terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003e1–2 wires per terminal (must be same type\/size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Requirement\u003c\/td\u003e\n\u003ctd\u003eCopper, rated ≥ 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Torque\u003c\/td\u003e\n\u003ctd\u003e0.37–0.50 ft-lbs (0.5–0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Mechanism\u003c\/td\u003e\n\u003ctd\u003eAdjustable rotary dials for module-to-carrier matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail or panel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eWiring and Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse high-quality copper conductors; two wires in a terminal must be identical in type and size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBarrier strips provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical separation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween terminals, reducing risk of shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor panel mounting, ensure a proper ground path through the backplane and carrier frame for EMI and transient protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between IC200CHS001 and IC200CHS002?\u003c\/strong\u003e\u003cbr\u003eThe IC200CHS001 uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style exposed screw terminal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for ring or spade lugs and high-vibration environments. The IC200CHS002 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebox-style\u003c\/strong\u003e, using cage terminals for wire insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this carrier be mounted on a non-conductive surface?\u003c\/strong\u003e\u003cbr\u003eYes, it can be panel-mounted, but ensure proper grounding through the backplane and carrier frame to maintain EMI shielding and transient protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790715644,"sku":"IC200CHS001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS0011.jpg?v=1771055433","url":"https:\/\/www.electronicplc.com\/products\/ic200chs001-ge-fanuc-versamax-barrier-style-i-o-carrier","provider":"Electronic PLC","version":"1.0","type":"link"}