{"product_id":"ic200mdl241-ge-fanuc-versamax-discrete-input-module","title":"General Electric IC200MDL241 VersaMax 16-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200MDL241 is a 16-point discrete input module designed for the VersaMax I\/O and control system. This module provides high-density input monitoring for 240 Volts AC applications, allowing for the integration of various field devices into a VersaMax PLC or I\/O station. It is engineered for reliability in industrial environments, featuring group isolation to protect the backplane and internal circuitry from potential field-side electrical disturbances.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete AC input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eOperating voltage rating of 240 Volts AC.\u003c\/li\u003e\n\u003cli\u003eIntegrated status monitoring via 16 individually numbered LEDs and one backplane communication LED.\u003c\/li\u003e\n\u003cli\u003eGroup isolation for enhanced signal integrity and system protection.\u003c\/li\u003e\n\u003cli\u003eCompact module design suitable for standard VersaMax I\/O carriers.\u003c\/li\u003e\n\u003cli\u003eBackplane current consumption of 110 milliamps.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily used within the GE VersaMax I\/O and control system architecture. It is suitable for industrial automation tasks requiring the monitoring of AC-powered sensors, limit switches, and pushbuttons in manufacturing, power generation, and process control facilities.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIC200MDL241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e240 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (On)\u003c\/td\u003e\n\u003ctd\u003e1 Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroup Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 Input LEDs, 1 Backplane LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the VersaMax I\/O carrier is properly mounted and secured before installing the module.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module from the carrier to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the I\/O carrier to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs where necessary to reduce noise pickup in high-EMI environments.\u003c\/li\u003e\n\u003cli\u003eHandle the module with care to avoid electrostatic discharge (ESD) damage to internal components.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring voltage matches the module specifications (240V AC) before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200MDL241?\u003c\/h3\u003e\u003cp\u003eThe IC200MDL241 is a discrete input module that detects the presence or absence of 240V AC signals from field devices and communicates this status to the VersaMax controller.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power for the inputs?\u003c\/h3\u003e\u003cp\u003eYes, the module is designed to monitor 240V AC signals; the field power must be supplied to the corresponding terminals on the I\/O carrier to energize the inputs.\u003c\/p\u003e\u003ch3\u003eHow are the inputs grouped?\u003c\/h3\u003e\u003cp\u003eThe module features group isolation, which provides electrical separation between the input groups and the backplane, helping to prevent ground loops and protect the control system.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50915451011324,"sku":"IC200MDL241","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a96dc156-41b6-494c-a7e6-f0893397dd3c.jpg?v=1785828263","url":"https:\/\/www.electronicplc.com\/products\/ic200mdl241-ge-fanuc-versamax-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}