{"product_id":"ic200pns002-ge-fanuc-versamax-profinet-network-scanner","title":"General Electric IC200PNS002 VersaMax PROFINET Scanner Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200PNS002 is a high-performance PROFINET Scanner (PNS) module within the VersaMax series. Designed for robust industrial communication, this module acts as a bridge between VersaMax I\/O stations and a PROFINET network. It features integrated fiber-optic connectivity and a built-in switch, making it ideal for environments requiring high immunity to electromagnetic interference (EMI). The module supports up to 2880 bytes of total I\/O data and is compatible with various network topologies, including daisy-chain, star, and ring configurations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual 100 Mbps SC-Duplex Multi-Mode Fiber (MMF) ports.\u003c\/li\u003e\n\u003cli\u003eSupports Media Redundancy Protocol (MRP) in client mode for ring topology reliability.\u003c\/li\u003e\n\u003cli\u003eIntegrated switch functionality for flexible network architecture.\u003c\/li\u003e\n\u003cli\u003eSupports redundant power supplies with hot-swap capability for de-energized units.\u003c\/li\u003e\n\u003cli\u003eFirmware field-upgradable via dedicated USB port.\u003c\/li\u003e\n\u003cli\u003eStandard PROFINET alarm and diagnostic reporting for efficient troubleshooting.\u003c\/li\u003e\n\u003cli\u003eConfiguration support via Classless InterDomain Routing (CIDR).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUrban infrastructure including water supply, sewage treatment, and tunnel ventilation.\u003c\/li\u003e\n\u003cli\u003eHigh-EMI environments such as power substations and large motor drive stations.\u003c\/li\u003e\n\u003cli\u003ePetrochemical facilities requiring fiber-optic isolation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eLong-distance I\/O communication in paper and steel mills.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PNS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003ePROFINET Scanner (PNS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e2 x SC-Duplex (Multi-Mode Fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Support\u003c\/td\u003e\n\u003ctd\u003eVersion 2.2 Class A IO-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10A at 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Data\u003c\/td\u003e\n\u003ctd\u003e2880 Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the module is installed in a clean, dry environment within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eThe module features an integrated carrier; no external carrier is required for mounting.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure fiber-optic cables are routed away from high-voltage power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the PROFINET device name is correctly assigned via the network port using a DCP-compliant tool.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables and proper grounding practices to minimize potential EMI\/RFI impact on the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200PNS002?\u003c\/h3\u003e\u003cp\u003eThe IC200PNS002 serves as a PROFINET Scanner that connects VersaMax I\/O modules to a PROFINET network via fiber-optic media.\u003c\/p\u003e\u003ch3\u003eCan the USB port be used for configuration?\u003c\/h3\u003e\u003cp\u003eNo, the USB port on the IC200PNS002 is reserved exclusively for firmware updates. Network configuration and device naming must be performed through the fiber-optic ports using Proficy Machine Edition.\u003c\/p\u003e\u003ch3\u003eDoes the module support redundant power?\u003c\/h3\u003e\u003cp\u003eYes, the module supports redundant power supplies, and the secondary supply can be hot-swapped if it is de-energized.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50517505212668,"sku":"IC200PNS002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_da496713-e2fd-4956-bd3e-b0880786e013.jpg?v=1784770372","url":"https:\/\/www.electronicplc.com\/products\/ic200pns002-ge-fanuc-versamax-profinet-network-scanner","provider":"Electronic PLC","version":"1.0","type":"link"}