{"product_id":"ic610mdl116-ge-fanuc-series-one-analog-input-module","title":"GE Fanuc IC610MDL116 Series One Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC610MDL116 is a high-performance analog input module engineered for the GE Fanuc Series One programmable logic controller system. This module features four independent input channels capable of processing both voltage and current signals, making it an essential component for precision monitoring in industrial processes such as chemical flow regulation, temperature tracking, and pressure sensing in refinery or power plant applications. By utilizing a rapid successive approximation conversion method, the module delivers an 8-bit binary resolution in under 2 ms, ensuring high-fidelity data acquisition that facilitates real-time control adjustments and minimizes system latency to reduce operational downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour independent input channels for versatile signal monitoring.\u003c\/li\u003e\n\u003cli\u003eJumper-selectable input ranges for flexible field instrumentation adaptation.\u003c\/li\u003e\n\u003cli\u003eDifferential input configuration to enhance signal integrity and reject common-mode noise.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance (\u0026gt; 1 Megaohm) for voltage signals to minimize loading effects.\u003c\/li\u003e\n\u003cli\u003eRapid 8-bit binary resolution conversion within 2 ms.\u003c\/li\u003e\n\u003cli\u003eDesigned for continuous duty in demanding industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for integration into Series One PLC systems, commonly used for process control, chemical flow regulation, temperature monitoring, and pressure sensing in industrial facilities such as refineries and power plants.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries One\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e4-Channel Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e8-Bit Binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e1 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 Megaohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e2 ms (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eSuccessive Approximation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirements\u003c\/td\u003e\n\u003ctd\u003e25 VDC, 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the Series One rack to ensure signal stability.\u003c\/li\u003e\n\u003cli\u003eVerify that jumper settings for input ranges are correctly configured for the specific field sensors before applying power.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the control cabinet to maintain operating temperatures within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) protection protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC610MDL116?\u003c\/h3\u003e\u003cp\u003eThe IC610MDL116 is an analog input module designed to convert voltage or current signals from field devices into digital data for processing by the GE Fanuc Series One PLC.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eYes, the module requires an external power supply of 25 VDC at 65 mA for operation.\u003c\/p\u003e\u003ch3\u003eCan this module handle both voltage and current inputs?\u003c\/h3\u003e\u003cp\u003eYes, the module supports both 1-5 VDC and 4-20 mA current loop signals, which are selectable via internal jumpers.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50969143214332,"sku":"IC610MDL116","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ac3cbd7a-d61e-4c0a-9947-0bbe28ed5518.jpg?v=1786499157","url":"https:\/\/www.electronicplc.com\/products\/ic610mdl116-ge-fanuc-series-one-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}