{"product_id":"ic670mdl241-ge-fanuc-field-control-240-vac-input-module","title":"General Electric IC670MDL241 16-Point 240VAC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC670MDL241 is a 16-point discrete input module designed for the GE Fanuc Field Control I\/O system. This module is engineered to monitor high-voltage AC signals, providing reliable interface capabilities for industrial control applications. It organizes its 16 inputs into two groups, allowing for flexible wiring and isolation between input sections. The module communicates with the Bus Interface Unit (BIU) to provide real-time status data to the controller.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete input points organized into 2 groups of 8.\u003c\/li\u003e\n\u003cli\u003eRated for 240 VAC nominal operation.\u003c\/li\u003e\n\u003cli\u003e250 VAC continuous isolation between the two input groups.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for each input point and a module power (PWR) status LED.\u003c\/li\u003e\n\u003cli\u003eDesigned for vertical mounting within the Field Control rack system.\u003c\/li\u003e\n\u003cli\u003eInternal circuitry includes a network of resistors and capacitors for input filtering and optoisolators for logic-to-field isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCNC Machinery and Metallurgy control systems.\u003c\/li\u003e\n\u003cli\u003eOil, Gas, and Petrochemical process control.\u003c\/li\u003e\n\u003cli\u003eAutomotive manufacturing assembly lines.\u003c\/li\u003e\n\u003cli\u003eWater treatment and municipal engineering systems.\u003c\/li\u003e\n\u003cli\u003ePlastic and textile manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e155 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 40 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e4.0 to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e0 to 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input Current\u003c\/td\u003e\n\u003ctd\u003e8.2 mA per point @ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eConnections\u003c\/h3\u003e\u003cp\u003eField devices such as pushbuttons, limit switches, or auxiliary contacts are connected between the 240 VAC \"Hot\" line and the specific input terminal. The neutral line is common for all points within a single group. Each group requires an external 240 VAC power source for operation.\u003c\/p\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for vertical mounting; ensure adequate clearance for airflow and cable management.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI interference in high-voltage environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the Bus Interface Unit (BIU) is properly seated and providing logic power before commissioning.\u003c\/li\u003e\n\u003cli\u003eObserve ESD precautions when handling the module to prevent damage to internal sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC670MDL241?\u003c\/h3\u003e\u003cp\u003eIt is a 16-point discrete input module belonging to the GE Fanuc Field Control I\/O family, designed to interface 240VAC signals with the control system.\u003c\/p\u003e\u003ch3\u003eWhat is the input voltage range?\u003c\/h3\u003e\u003cp\u003eThe module operates with an input voltage range of 0 to 265 VAC at a frequency of 47 to 63 Hz.\u003c\/p\u003e\u003ch3\u003eHow do the LEDs function?\u003c\/h3\u003e\u003cp\u003eThe module features 16 individual LEDs to show the status of each input point, and a PWR LED that indicates the presence of both backplane logic power and user field power.\u003c\/p\u003e\u003ch3\u003eIs there isolation between points?\u003c\/h3\u003e\u003cp\u003eThere is no isolation between individual points within a single group, but there is 250 VAC continuous isolation provided between the two groups of 8 points.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50733881786620,"sku":"IC670MDL241","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5d5451a3-11f6-4c29-9c04-bd357803f5c6.jpg?v=1785285369","url":"https:\/\/www.electronicplc.com\/products\/ic670mdl241-ge-fanuc-field-control-240-vac-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}