{"product_id":"ic693mdl640-ge-fanuc-series-90-30-input-module","title":"General Electric IC693MDL640 90-30 Series 16-Point 24VDC Positive Logic Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC693MDL640 is a 24VDC positive logic input module designed for the General Electric Series 90-30 PLC system. This module provides 16 discrete input points grouped together with a common power input terminal. It is engineered to sink current from input devices to the user common or negative power bus, making it compatible with a variety of field devices including pushbuttons, limit switches, and proximity sensors. Each input point features an integrated LED status indicator to provide visual confirmation of the ON\/OFF state.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete input points in a single group\u003c\/li\u003e\n\u003cli\u003e24VDC positive logic configuration\u003c\/li\u003e\n\u003cli\u003e1500V RMS isolation between field and logic sides\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each input point\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Series 90-30 baseplates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAssembly line tracking and sensor signal monitoring\u003c\/li\u003e\n\u003cli\u003eInjection molding machine cycle control via limit and pressure switches\u003c\/li\u003e\n\u003cli\u003eFluid level and valve position monitoring in water treatment systems\u003c\/li\u003e\n\u003cli\u003eChemical delivery system dosing control\u003c\/li\u003e\n\u003cli\u003eSubstation circuit breaker and status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-30 to +30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e15 to 30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e-30 to 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e4mA (minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e1.5mA (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e7ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500V RMS (field to logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure all power to the PLC rack is disconnected before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eThe module can be installed in any I\/O slot of a 5-slot or 10-slot baseplate, excluding Slot 1 (reserved for the CPU).\u003c\/li\u003e\n\u003cli\u003eAlign the module carefully with the guide rails on the baseplate.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly into the backplane connector until it is fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated latch at the bottom to ensure a reliable connection.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the enclosure to ensure the module operates within its specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the GE IC693MDL640?\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC693MDL640 is a 24-volt DC, 16-point Positive Logic Input module designed for the Series 90-30 PLC system. It features 16 input points in one group with a common power input terminal.\u003c\/p\u003e\u003ch3\u003eWhat is the rated voltage of the IC693MDL640?\u003c\/h3\u003e\u003cp\u003eIt operates on a rated voltage of 24 VDC.\u003c\/p\u003e\u003ch3\u003eWhere can the IC693MDL640 be installed?\u003c\/h3\u003e\u003cp\u003eIt can be installed in any I\/O slot on the 5-slot or 10-slot backplane of a 90-30 series PLC system, excluding the CPU slot.\u003c\/p\u003e\u003ch3\u003eHow do I know if an input is active?\u003c\/h3\u003e\u003cp\u003eThere are 16 status LEDs at the top of the module that indicate the ON\/OFF status of each individual input point.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50464691192060,"sku":"IC693MDL640","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7dd3056e-3d0b-42e0-b369-9219d6e96792.jpg?v=1784691291","url":"https:\/\/www.electronicplc.com\/products\/ic693mdl640-ge-fanuc-series-90-30-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}