{"product_id":"ic693mdl742-ge-fanuc-series-90-30-digital-output-module","title":"General Electric IC693MDL742 90-30 Series 16-Point 12\/24 VDC Output Module","description":"\u003cp\u003eThe General Electric IC693MDL742 is a discrete output module designed for the GE Fanuc 90-30 Series PLC platform. This module provides 16 output points, supporting positive logic configurations for interfacing the PLC with external devices such as relays, solenoid-actuated devices, contactors, and indicator lamps. It features integrated Electronic Short Circuit Protection (ESCP) to safeguard the module circuitry from damage in the event of a short circuit condition.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete output channels with individual status indicators.\u003c\/li\u003e\n\u003cli\u003eIntegrated Electronic Short Circuit Protection (ESCP) with fault LED indication.\u003c\/li\u003e\n\u003cli\u003eSupports 12\/24 VDC output voltage range (+20%, -15%).\u003c\/li\u003e\n\u003cli\u003eBackplane power consumption of 130 mA when all outputs are energized.\u003c\/li\u003e\n\u003cli\u003eCompact single-slot design for 90-30 Series baseplates.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing and assembly lines.\u003c\/li\u003e\n\u003cli\u003eHigh-speed packaging and material handling systems.\u003c\/li\u003e\n\u003cli\u003eFood and beverage processing equipment.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial applications including mining and steel production.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment utility systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL742\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC (+20%, -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Per Point)\u003c\/td\u003e\n\u003ctd\u003e1.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Per Group)\u003c\/td\u003e\n\u003ctd\u003e4 A at 50 degC; 3 A at 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e5.2 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-state Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e2 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.2 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eThe module occupies a single slot and can be installed in any available slot on a 90-30 Series baseplate, excluding dedicated CPU, power supply, or specialty module slots.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for output connections where required by the application environment.\u003c\/li\u003e\n\u003cli\u003eVerify that the load requirements do not exceed the per-point or per-group current ratings to prevent triggering the ESCP.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the purpose of the built-in Electronic Short Circuit Protection (ESCP)?\u003c\/h3\u003e\u003cp\u003eThe ESCP monitors the common signal of each output group. If a short circuit is detected, the module protects the circuit board from damage and illuminates the \"F\" LED to signal the fault condition.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum current capacity per group?\u003c\/h3\u003e\u003cp\u003eThe module supports a maximum of 4 Amperes per group at 50 degC, reducing to 3 Amperes per group at 60 degC.\u003c\/p\u003e\u003ch3\u003eHow is the module status monitored?\u003c\/h3\u003e\u003cp\u003eThe module features individual channel indicators that display the energization state of each output, as well as a dedicated fault indicator for short-circuit conditions.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51006447714556,"sku":"IC693MDL742","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b6f7bea5-16d9-4c09-b6d5-80c872381ea4.jpg?v=1787507583","url":"https:\/\/www.electronicplc.com\/products\/ic693mdl742-ge-fanuc-series-90-30-digital-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}