{"product_id":"ic694mdl754-discrete-output-module-ge-fanuc","title":"IC694MDL754 Discrete Output Module GE Fanuc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL754\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-point discrete output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Short Circuit Protection (ESCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced reliability, making it ideal for precise switching of 12\/24 VDC loads in demanding industrial automation applications. Outputs are divided into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo isolated groups of 16\u003c\/strong\u003e, allowing flexible power segregation and minimizing cross-channel interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC694MDL754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30, PACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32 (two isolated groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.75 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC (1 minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e300 mA max from 5 VDC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ID\u003c\/td\u003e\n\u003ctd\u003e0x059h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eElectronic Short Circuit Protection (ESCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Characteristics\u003c\/td\u003e\n\u003ctd\u003eNo derating at 24 VDC; derating at 30 VDC above 42°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density discrete output control in industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSegregated control loops for different machine sections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable switching for 12\/24 VDC actuators, solenoids, and relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpace-constrained PLC or PACSystems racks requiring robust short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does ESCP mean?\u003c\/strong\u003e\u003cbr\u003eESCP stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Short Circuit Protection\u003c\/strong\u003e, which detects and limits current during a short-circuit event to prevent permanent damage to the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be used at 30 VDC in high temperatures?\u003c\/strong\u003e\u003cbr\u003eYes, but\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal derating applies above 42°C\u003c\/strong\u003e. Consult official derating curves to ensure safe operation at 30 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the output groups independent?\u003c\/strong\u003e\u003cbr\u003eYes, the module has\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo isolated groups of 16 outputs\u003c\/strong\u003e, allowing separate power sources for each group to minimize interference and improve diagnostic clarity.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723836156,"sku":"IC694MDL754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694MDL7541.jpg?v=1773387059","url":"https:\/\/www.electronicplc.com\/products\/ic694mdl754-discrete-output-module-ge-fanuc","provider":"Electronic PLC","version":"1.0","type":"link"}