{"product_id":"ks1-07-b-signal-cable-yokogawa","title":"KS1-07*B Signal Cable YOKOGAWA","description":"\u003cp\u003eConfigured for high-density signal interconnection, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA KS1-07*B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKS1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignal Cable) provides direct physical\/electrical execution for data transit between field terminal boards and I\/O module assemblies within CENTUM series control architectures.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-9 citation-end-9\"\u003eThis cable assembly utilizes a 40-pin to 40-pin interface to maintain deterministic signal paths across the distributed control system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe KS1-07*B is defined by the following configuration attributes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-8\"\u003e\u003c\/span\u003e\u003cstrong\u003eKS1\u003c\/strong\u003e\u003cspan class=\"citation-8 citation-end-8\"\u003e: Base model designation for the multi-pin signal cable.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-7\"\u003e\u003c\/span\u003e\u003cstrong\u003e07\u003c\/strong\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003e: Specifies a cable length of 7 meters.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-6\"\u003e\u003c\/span\u003e\u003cstrong\u003e*B\u003c\/strong\u003e\u003cspan class=\"citation-6 citation-end-6\"\u003e: Denotes Style B construction, ensuring compatibility with current CENTUM VP and CS series interface standards.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS1-07*B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 cm x 5.1 cm x 38.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePin Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40-pin to 40-pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-core Signal Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe KS1-07*B is engineered to facilitate reliable data exchange by maintaining consistent electrical performance across its 40-pin interface. This high-density connection supports the propagation of analog and digital signals, ensuring that signal amplitude remains within the strictly defined parameters required for CENTUM VP fault-tolerant networks. The cable assembly features integrated shielding to mitigate electromagnetic interference (EMI) risks in high-noise industrial cabinet environments, preserving signal fidelity for process control instrumentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this cable suitable for use in high-vibration areas?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cable connectors are designed for secure attachment to module backplanes and terminal boards, providing mechanical retention that resists loosening due to industrial vibration profiles. Ensure the connector locking mechanisms are fully engaged upon installation.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple KS1 cables be connected in series to extend the length?\u003c\/p\u003e\n\u003cp\u003eA: No, the KS1 cable assembly is designed for point-to-point connections between a terminal board and an I\/O module. Extending the distance via daisy-chaining is not recommended as it increases contact resistance and potential for signal degradation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect both 40-pin connectors for bent or oxidized pins prior to installation. A compromised pin connection can lead to intermittent I\/O communication errors or signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen routing the cable, maintain a minimum bending radius as specified by the cable construction to prevent internal conductor fatigue or shield damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep the signal cable physically separated from high-voltage power lines and AC motor drive cabling to minimize inductive noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the connector vertically with the port on the I\/O module or terminal board and push firmly until the locking mechanism is fully secured.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the cable to the cabinet framework using cable ties or management channels, ensuring that the connector is not under physical tension or strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49257883697404,"sku":"KS1-07*B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/KS1-201.jpg?v=1780971137","url":"https:\/\/www.electronicplc.com\/products\/ks1-07-b-signal-cable-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}