{"product_id":"modicon-quantum-140drc83000-discrete-relay-output-brand-new","title":"Modicon Quantum 140DRC83000 Discrete Relay Output Brand New","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric 140DRC83000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density relay discrete output module for the Modicon Quantum automation platform. This module provides 8 independent channels, utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eForm C (1 NO\/NC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay contacts to switch both AC and DC loads effectively. It manages critical field devices such as solenoids, motor starters, and indicator lamps with high precision. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring it meets the rigorous demands of power generation, water treatment, and heavy manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140DRC83000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Relay Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Form\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForm C (1 NO\/NC per channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Output Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–250 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Output Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–30 V DC \/ 30–150 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 A at 250V AC \/ 30V DC (Resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1250 VA (Resistive)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1780 Vrms AC between channels and bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms (State 0 to 1) \/ 20 ms (State 1 to 0)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Varistor (275 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Load Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Form C contact architecture allows engineers to control both normally open and normally closed circuits within a single module. It effortlessly handles diverse loads ranging from low-current signals to 5A resistive motor control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Surge Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated 275V varistors protect the module from voltage spikes often generated by inductive loads. This internal protection reduces the need for external snubbers and extends the lifespan of the relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExceptional Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 1780 Vrms AC isolation between individual channels and the backplane bus. This design prevents electrical noise or field-side faults from propagating back to the Quantum CPU, maintaining system integrity in high-interference areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTen front-facing LEDs provide instant visual status. A dedicated green \"Active\" LED confirms bus communication, while a red \"Fault\" LED signals external wiring or hardware issues, drastically reducing troubleshooting time during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between Form C and standard NO contacts in this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eForm C contacts provide a \"Changeover\" function, meaning each channel has one common, one normally open (NO), and one normally closed (NC) terminal. This allows you to toggle between two different circuits or fail-safe positions using a single output point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle inductive loads like large solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it supports inductive loads. However, for inductive applications, refer to the switching frequency formula (\u003cspan class=\"math-inline\"\u003e$F = 0.5\/I^2L$\u003c\/span\u003e) provided in the manual to ensure optimal electrical durability and prevent premature contact wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 140DRC83000 compatible with all Modicon Quantum Racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt adheres to the standard Quantum module format and draws 560 mA from the bus. It installs into any standard Quantum backplane, provided the power supply module (such as the 140CPS series) has sufficient current overhead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":49076534771964,"sku":"140DRC83000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8._3f1cf4ad-5c1b-4dfa-82fd-dc81619a5486.jpg?v=1778227059","url":"https:\/\/www.electronicplc.com\/products\/modicon-quantum-140drc83000-discrete-relay-output-brand-new","provider":"Electronic PLC","version":"1.0","type":"link"}