{"product_id":"mvi69-dfnt-prosoft-compactlogix-communication-module","title":"ProSoft MVI69-DFNT CompactLogix EtherNet\/IP Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ProSoft MVI69-DFNT is a high-performance communication module designed to provide EtherNet\/IP connectivity for Rockwell Automation CompactLogix and MicroLogix 1500 LRP platforms. Acting as a bridge within the 1769 backplane, this module facilitates robust data exchange between the PLC and external EtherNet\/IP-enabled devices. It supports both client and server operations, allowing for flexible integration into complex industrial automation architectures, including manufacturing, material handling, and process control systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Integration:\u003c\/strong\u003e Designed specifically for the 1769 CompactLogix backplane, occupying a single slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Acts as an EtherNet\/IP Client\/Server interface, supporting explicit messaging for efficient data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommand Capacity:\u003c\/strong\u003e Supports up to 100 user-configurable commands for read\/write operations to remote network devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServer Functionality:\u003c\/strong\u003e Includes 20 server connections to handle requests from external network equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor Compatibility:\u003c\/strong\u003e Compatible with a wide range of CompactLogix processors (L20, L30, L31, L32, L35) and L43\/L45 models (requires RSLogix 5000 v16.03 or later).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Support:\u003c\/strong\u003e Fully compatible with MicroLogix 1500 LRP controllers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MVI69-DFNT is ideal for industrial environments requiring reliable network isolation and dedicated communication ports. It is commonly used to integrate third-party EtherNet\/IP devices, manage network traffic, and extend the communication capabilities of existing CompactLogix control systems.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69-DFNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Width\u003c\/td\u003e\n\u003ctd\u003eSingle Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP (Explicit Messaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Commands\u003c\/td\u003e\n\u003ctd\u003e100 Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer Connections\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always remove power from the 1769 backplane before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeating:\u003c\/strong\u003e Ensure the module is properly aligned with the backplane connector and fully seated in the slot. Secure the module using the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Follow standard industrial grounding practices for the 1769 system to minimize electrical noise and EMI interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded Ethernet cabling for network connections to maintain signal integrity in high-EMI industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use an anti-static wrist strap or similar ESD protection when handling the module to prevent damage to sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes the MVI69-DFNT require special software for configuration?\u003c\/h3\u003e\u003cp\u003eThe module is typically configured using ProSoft Configuration Builder (PCB) software, which allows you to define the communication parameters and command lists required for your specific application.\u003c\/p\u003e\u003ch3\u003eCan this module be used in a remote I\/O rack?\u003c\/h3\u003e\u003cp\u003eThe MVI69-DFNT is designed for use in the local 1769 backplane of a CompactLogix controller. It is not intended for use in remote I\/O chassis.\u003c\/p\u003e","brand":"Prosoft","offers":[{"title":"Default Title","offer_id":50604760137980,"sku":"MVI69-DFNT","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_65e14ed1-2e3d-466a-8e7b-2d3e5929d1c6.jpg?v=1784861276","url":"https:\/\/www.electronicplc.com\/products\/mvi69-dfnt-prosoft-compactlogix-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}