{"product_id":"nc1x1604-versatile-digital-input-module-yokogawa","title":"NC1X1604 Versatile Digital Input Module Yokogawa","description":"\u003cp\u003eConfigured for high-density signal acquisition within PLC architectures, the \u003cstrong\u003eYokogawa NC1X1604\u003c\/strong\u003e (\u003cstrong\u003eNC1X1604\u003c\/strong\u003e Digital Input Module) provides direct physical and electrical execution of 16-channel digital state monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNC1X1604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e88 mm x 58 mm x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12-24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eContact output (250 V AC\/DC, 0.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Backplane Performance\u003c\/h3\u003e\n\u003cp\u003eThe NC1X1604 architecture is optimized for high-density industrial control environments, facilitating efficient I\/O density scaling within Yokogawa FA-M3 and STARDOM platforms. The module manages deterministic input state capture, ensuring that backplane bus communication velocity remains consistent across all 16 channels. The hardware includes internal circuitry for signal debouncing and level shifting, allowing for direct interface with both 12 V and 24 V logic levels. By maintaining galvanic isolation between the field-side inputs and the backplane logic, the module preserves signal integrity in high-EMI environments, preventing false triggering or state corruption during system operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NC1X1604 support hot-swapping during active PLC operation?\u003c\/p\u003e\n\u003cp\u003eA: No. To prevent potential backplane bus errors or accidental contact damage, ensure the PLC rack power is de-energized before inserting or removing the module.\u003c\/p\u003e\n\u003cp\u003eQ: Can the contact outputs be used to drive high-inductive loads directly?\u003c\/p\u003e\n\u003cp\u003eA: The contact outputs are rated for 0.5 A at 250 V AC\/DC. When driving inductive loads such as solenoid valves or relays, external suppression diodes or RC snubbers must be installed to protect the internal contacts from flyback voltage spikes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane connectors and module pins for structural integrity before installation to ensure a secure electrical connection.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring polarity matches the 12-24 V DC input requirements; ensure common signal returns are correctly tied to the system ground.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded wiring for input signal paths to minimize the influence of crosstalk and external electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eAfter seating the module, verify the mechanical lock to ensure the unit remains secure against cabinet vibration.\u003c\/li\u003e\n\u003cli\u003ePerform a localized point-check on all 16 channels using the PLC configuration software to confirm state transitions are registering accurately prior to integration with control logic.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49245961683196,"sku":"NC1X1604","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NC1X16042.jpg?v=1783043696","url":"https:\/\/www.electronicplc.com\/products\/nc1x1604-versatile-digital-input-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}