{"product_id":"nfta4s-10-yokogawa-analog-input-module-new-original-stock","title":"NFTA4S-10 Yokogawa Analog Input Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for analog signal acquisition in STARDOM controller platforms, the \u003cstrong\u003eYokogawa NFTA4S-10\u003c\/strong\u003e (\u003cstrong\u003eNFTA4S-10\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution of 16-channel analog-to-digital signal conversion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFTA4S-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard STARDOM I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRefer to STARDOM backplane power budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Conversion\u003c\/h3\u003e\n\u003cp\u003eThe module functions as the primary interface for field instrumentation, accepting standard 4-20 mA or 1-5 V DC inputs and performing high-resolution conversion for controller processing. While the architecture utilizes non-isolated channels, it maintains a consistent 16-bit conversion depth across all 16 inputs to ensure process data granularity. The module is engineered to operate within an industrial temperature spectrum, ensuring the analog-to-digital conversion circuits remain stable under varying environmental conditions without degradation of the +\/- 0.1% accuracy threshold.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the NFTA4S-10 support hot-swapping within the controller rack?\u003c\/p\u003e\n\u003cp\u003eA: The ability to perform hot-swapping depends on the specific STARDOM rack backplane and power distribution system. Consult the system hardware manual to confirm support for online maintenance procedures for this module.\u003c\/p\u003e\n\u003cp\u003eQ: How is the input type selected for the 16 channels?\u003c\/p\u003e\n\u003cp\u003eA: Input configuration for 4-20 mA or 1-5 V DC is typically managed through the STARDOM engineering software parameters, which control the internal signal path and shunt resistance logic for the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the system power is isolated before installing the module into the rack to prevent damage to the backplane communication pins.\u003c\/li\u003e\n\u003cli\u003eFor 4-20 mA loop inputs, ensure proper loop continuity and check for correct load resistance within the field wiring configuration.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all analog signals to minimize electromagnetic interference (EMI) and potential signal noise in the non-isolated channel architecture.\u003c\/li\u003e\n\u003cli\u003eVerify that field signal commons are compatible with the module's non-isolated design to avoid ground loops between connected instruments.\u003c\/li\u003e\n\u003cli\u003ePerform an analog loop check using a calibrated signal generator to verify that the digitized input values at the engineering station correspond to the input source levels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49174425927932,"sku":"NFTA4S-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFTB5S-002.jpg?v=1780882795","url":"https:\/\/www.electronicplc.com\/products\/nfta4s-10-yokogawa-analog-input-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}