{"product_id":"operator-interface-panel-woodward-series-5453-203","title":"Operator Interface Panel Woodward Series 5453-203","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized human-machine interface (HMI) developed by Woodward for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet and MicroNet Plus control platforms\u003c\/strong\u003e. This 2-line alphanumeric display panel provides operators with direct access to critical turbine and engine control data, including speed, load, and diagnostic fault codes, without requiring a remote engineering workstation.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for harsh industrial environments such as turbine control rooms, offshore engine rooms, and power plant control cabinets. The high-contrast display ensures visibility under varying lighting conditions, while the durable tactile keypad allows operation even when wearing protective industrial gloves.\u003c\/p\u003e\n\u003cp\u003eThis HMI serves as a local operator interface for monitoring system health and performing basic control interactions during commissioning, troubleshooting, and routine maintenance activities. It communicates directly with the MicroNet CPU through dedicated serial or Ethernet links (configuration dependent).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5453-203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroNet Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e2-Line Alphanumeric Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring and alarm acknowledgment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eMicroNet serial or Ethernet (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eIndustrial tactile membrane keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e305 mm × 356 mm × 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine governor control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge reciprocating engine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plant operator panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical functions include monitoring lubrication pressure, turbine speed, load sharing status, and synchronization parameters.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5453-203 be used to modify PID tuning parameters?\u003c\/strong\u003e\u003cbr\u003eYes. If permitted by security settings in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP (Graphical Application Programmer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware, authorized operators can adjust control setpoints and tuning parameters directly from the keypad interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this display compatible with Netcon 5000 systems?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for MicroNet architecture. Communication protocols and mounting designs differ from older Netcon platforms, so compatibility must be verified before retrofitting.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751557884,"sku":"5453-203","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5453-203.jpg?v=1772435089","url":"https:\/\/www.electronicplc.com\/products\/operator-interface-panel-woodward-series-5453-203","provider":"Electronic PLC","version":"1.0","type":"link"}