{"product_id":"power-supply-module-pw402-yokogawa-new-original-stock","title":"Power Supply Module PW402 YOKOGAWA New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA PW402\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW402\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power regulation within DCS process control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePW402\u003c\/strong\u003e: Standard high-power configuration providing dual output voltage rails of +12 VDC and +24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePW402-S2\u003c\/strong\u003e: Low-power configuration variant optimized for single-rail 24 VDC output distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePW402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.1 cm x 22.9 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eLoad dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e100-120 VAC or 220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e+12 VDC and +24 VDC (Base model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Power Stabilization\u003c\/h3\u003e\n\u003cp\u003eThe module integrates specialized circuitry for channel-to-channel isolation and voltage regulation required in DCS instrumentation loops. To maintain the requisite output stability, the power supply utilizes internal feedback loops to compensate for variations in line voltage. The +12 VDC and +24 VDC rails are engineered for low ripple characteristics, facilitating stable operation for sensitive analog input and output modules within the YOKOGAWA ecosystem. Proper thermal management is required, as the unit dissipates heat during high-load operations, necessitating adequate cabinet ventilation to prevent internal component fatigue.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary considerations for the input voltage configuration?\u003c\/p\u003e\n\u003cp\u003eA: The input stage is designed for dual-range operation. Users must verify the specific model variation requirements (100-120 VAC or 220-240 VAC) prior to commissioning to ensure the internal transformer taps are correctly matched to the field supply.\u003c\/p\u003e\n\u003cp\u003eQ: How should the multi-output rails be managed under load?\u003c\/p\u003e\n\u003cp\u003eA: The PW402 provides separate output rails for +12 VDC and +24 VDC. Load distribution should be balanced to prevent current saturation on either rail. Consult the system power budget documentation to confirm that total wattage consumption does not exceed the power supply design limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module vertically within the cabinet rack to ensure that cooling vents are not obstructed and that natural convection flow is maintained.\u003c\/li\u003e\n\u003cli\u003eEnsure the protective earth (PE) connection is secured to the main cabinet chassis to maintain signal reference integrity and provide a path for fault currents.\u003c\/li\u003e\n\u003cli\u003eRoute the output DC distribution wiring through segregated cable trays, keeping power conductors separate from low-voltage I\/O signal lines to reduce electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eTorque terminal screws to the manufacturer-specified values to ensure low-resistance contact and prevent intermittent power delivery caused by thermal expansion or vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49134301872380,"sku":"PW402","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PW402.jpg?v=1779760807","url":"https:\/\/www.electronicplc.com\/products\/power-supply-module-pw402-yokogawa-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}