{"product_id":"prosoft-mvi69-mnet-compactlogix-modbus-tcp-ip-module","title":"ProSoft MVI69-MNET Modbus TCP\/IP Communication Module for CompactLogix","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ProSoft MVI69-MNET is a high-performance Modbus TCP\/IP communication module designed specifically for integration with Rockwell Automation CompactLogix programmable automation controllers. This module allows the CompactLogix processor to interface seamlessly with Modbus TCP\/IP-enabled devices, acting as either a Client or a Server to facilitate data exchange across industrial Ethernet networks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for seamless integration into the Rockwell CompactLogix platform.\u003c\/li\u003e\n\u003cli\u003eSupports up to 5,000 registers for extensive data handling.\u003c\/li\u003e\n\u003cli\u003eConfigurable as a Modbus TCP\/IP Client or Server.\u003c\/li\u003e\n\u003cli\u003eSupports up to 100 Client commands for complex network architectures.\u003c\/li\u003e\n\u003cli\u003eData transfer managed via standard ladder logic for simplified programming.\u003c\/li\u003e\n\u003cli\u003eOccupies a single slot in the CompactLogix chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in industrial automation environments where CompactLogix controllers must communicate with third-party devices such as variable frequency drives (VFDs), power meters, remote I\/O, and other controllers supporting the Modbus TCP\/IP protocol. It is ideal for process control, energy management, and machine-to-machine communication.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eMVI69-MNET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eRockwell CompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 Single-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Registers\u003c\/td\u003e\n\u003ctd\u003e5,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Client Commands\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Load\u003c\/td\u003e\n\u003ctd\u003e800 mA max @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Method\u003c\/td\u003e\n\u003ctd\u003eLadder Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the CompactLogix chassis is powered down before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated slot until the locking mechanism engages securely.\u003c\/li\u003e\n\u003cli\u003eUse shielded Ethernet cabling for all network connections to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the chassis backplane to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfigure the module parameters using the appropriate ProSoft configuration software or via ladder logic integration as specified in the user manual.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the MVI69-MNET compatible with all CompactLogix controllers?\u003c\/h3\u003e\u003cp\u003eThe MVI69-MNET is designed for the 1769 CompactLogix platform. Please verify your specific processor firmware and backplane compatibility in the ProSoft technical documentation before installation.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eNo, the module draws its operating power directly from the CompactLogix backplane. Ensure your power supply is sized to accommodate the 800 mA current load.\u003c\/p\u003e","brand":"ProSoft","offers":[{"title":"Default Title","offer_id":50553870287100,"sku":"MVI69-MNET","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8f12549f-fda0-4a88-9248-8c31013b0581.jpg?v=1784796597","url":"https:\/\/www.electronicplc.com\/products\/prosoft-mvi69-mnet-compactlogix-modbus-tcp-ip-module","provider":"Electronic PLC","version":"1.0","type":"link"}