{"product_id":"ps13-b-yokogawa-power-supply-module-new-original-stock","title":"PS13*B Yokogawa Power Supply Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for power distribution in industrial control platforms, the \u003cstrong\u003eYokogawa PS13*B\u003c\/strong\u003e (\u003cstrong\u003ePS13*B\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution of voltage regulation and system power delivery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePS13*B\u003c\/strong\u003e series utilizes a flexible suffix structure to designate specific input\/output voltage configurations and power output capacities. Consult the system hardware manual to match the specific model suffix with the required backplane power load and input voltage source.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePS13*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard industrial PSU form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eIndustrial cabinet mount dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade (consult system manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRefer to load capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\/Output\u003c\/td\u003e\n\u003ctd\u003eRegulated DC voltage delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePower Regulation and System Stability\u003c\/h3\u003e\n\u003cp\u003eThe module functions as a primary DC power source, providing stable voltage regulation to the backplane bus and connected I\/O hardware. To ensure long-term operational consistency, the unit incorporates internal surge protection and output filtering to mitigate electrical noise generated by upstream power grid fluctuations. The modular design enables efficient heat dissipation, supporting continuous operation under the varying electrical loads typically encountered in process control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can multiple PS13*B modules be connected in parallel for current sharing?\u003c\/p\u003e\n\u003cp\u003eA: Parallel operation is subject to the specific backplane design and module revision. Verify the system technical documentation to determine if the hardware supports active current sharing or if blocking diodes are required to prevent back-feeding between units.\u003c\/p\u003e\n\u003cp\u003eQ: How is the thermal load managed during high-demand periods?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on passive convection cooling within the cabinet. Ensure that the specified installation clearances are maintained to prevent thermal accumulation and premature degradation of internal components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the incoming power source matches the input voltage rating of the specific \u003cstrong\u003ePS13*B\u003c\/strong\u003e model suffix before connecting the primary power leads.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage AC input lines separately from low-voltage DC output and signal cabling to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eSecure the module onto the rack or DIN rail, ensuring a low-impedance electrical bond is established between the chassis and the system protective earth (PE) ground.\u003c\/li\u003e\n\u003cli\u003eMeasure the output voltage at the backplane terminals under no-load conditions to confirm operational status before connecting the control system modules.\u003c\/li\u003e\n\u003cli\u003eInspect the wiring connections periodically to ensure that terminal screws remain tightened, mitigating the risk of high-resistance contact points.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49174466560252,"sku":"S9981DE-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PS13B.jpg?v=1780971137","url":"https:\/\/www.electronicplc.com\/products\/ps13-b-yokogawa-power-supply-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}