{"product_id":"schneider-electric-140ari03010-rtd-analog-input-module","title":"Schneider Electric 140ARI03010 RTD Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140ARI03010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision RTD temperature input module developed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Quantum Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation architecture. This module is designed for direct temperature measurement from Resistance Temperature Detector (RTD) sensors, eliminating the need for external signal conditioning transmitters in many process control applications.\u003c\/p\u003e\n\u003cp\u003eThe module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 independent high-resolution analog input channels\u003c\/strong\u003e, enabling accurate thermal monitoring in industrial environments with high electrical noise. Its built-in isolation and filtering technologies help maintain stable and reliable temperature acquisition for critical process control loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eQuantum Automation Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e140ARI03010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD Temperature Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000, Ni100, Ni1000, Cu10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms (1 minute, channel-to-bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e450 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e31 cm × 16.5 cm × 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 140ARI03010 is commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFurnace and boiler temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical production process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC environmental monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially useful in applications requiring direct RTD probe connection, reducing wiring complexity and signal conversion errors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 140ARI03010 support multiple RTD wiring configurations?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire, 3-wire, and 4-wire RTD connections\u003c\/strong\u003e, allowing for lead resistance compensation to improve measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module detect sensor faults?\u003c\/strong\u003e\u003cbr\u003eThe module includes built-in diagnostics that detect open circuits or short circuits. Faults are transmitted to the PLC CPU and typically displayed using the front-panel fault indicator LED.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48746750476540,"sku":"140ARI03010","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/140ARI030101_75524725-5214-4123-952f-90c944bdff3b.jpg?v=1772521831","url":"https:\/\/www.electronicplc.com\/products\/schneider-electric-140ari03010-rtd-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}