{"product_id":"schneider-electric-modicon-quantum-140ddo35300-discrete-output-module","title":"Schneider Electric Modicon Quantum 140DDO35300 Discrete Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DDO35300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric Modicon Quantum automation platform\u003c\/strong\u003e. This module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 solid-state output channels\u003c\/strong\u003e, facilitating the control of actuators, relays, and motor starters in a synchronized PLC environment. Engineered for high-speed logic execution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DDO35300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures precise switching with integrated diagnostic capabilities to maintain system uptime in mission-critical applications.\u003c\/p\u003e\n\u003cp\u003eThe module architecture features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour isolated groups of eight outputs each\u003c\/strong\u003e, providing robust electrical separation between different field circuits. This design minimizes the risk of total system failure caused by localized electrical faults.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Identification\u003c\/td\u003e\n\u003ctd\u003e140DDO35300 (Modicon Quantum Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e2 Output words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Logic\u003c\/td\u003e\n\u003ctd\u003ePositive Logic (Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Per Group\u003c\/td\u003e\n\u003ctd\u003e4 A per group (8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Per Module\u003c\/td\u003e\n\u003ctd\u003e16 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ms (Off to On) \/ \u0026lt; 1 ms (On to Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1780 V AC for 1 minute (between channels and bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e7.5 W typical + 0.5 W per energized output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eInternal module status and external power supply monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Use Cases\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized control of pneumatic solenoid valves in packaging lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density pilot light arrays for industrial HMI control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing with auxiliary contactors for heavy machinery startup sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the field power status monitored on this module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e140DDO35300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures LED indicators on the front panel that signal\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Power Fail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eif the external 24V DC supply is lost or drops below the operational threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal block?\u003c\/strong\u003e\u003cbr\u003eYes, it utilizes the standard Quantum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40-pin removable terminal block (140XTS00200)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor simplified field wiring and maintenance.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":48746746937596,"sku":"140DDO35300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/140ACI030001_b3583599-082d-4f31-940a-851474e9d439.jpg?v=1772610735","url":"https:\/\/www.electronicplc.com\/products\/schneider-electric-modicon-quantum-140ddo35300-discrete-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}