{"product_id":"schneider-electric-modicon-quantum-140dvo85300c-discrete-output-modules","title":"Schneider Electric 140DVO85300C Modicon Quantum Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric 140DVO85300C is a high-density discrete output module designed for the Modicon Quantum automation platform. Engineered for demanding industrial environments, this module provides 32 output channels capable of driving field devices such as solenoids, relays, and indicators. The unit features conformal coating to ensure reliable operation in environments exposed to humidity, chemical contaminants, and corrosive atmospheres. It provides galvanic isolation and real-time monitoring to protect the central processor from field-side faults, significantly reducing system downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete output channels for high-density control.\u003c\/li\u003e\n\u003cli\u003eConformal coating for enhanced protection against harsh environmental conditions.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between field outputs and the backplane.\u003c\/li\u003e\n\u003cli\u003eActive electronic fusing for autonomous channel fault isolation.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED matrix for real-time status diagnostics of communication, power, and individual channel logic.\u003c\/li\u003e\n\u003cli\u003eDesigned for compatibility with the Modicon Quantum backplane architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for critical industrial applications including oil and gas refining, power generation, and metallurgical mining processes where reliable digital signal control is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DVO85300C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Per Module\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VDC (channel-to-backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the Quantum backplane.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the rack slot to maintain proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eVerify that external field power is within the specified 10 to 30 VDC range before energizing.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring away from high-EMI sources to minimize signal interference.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the control cabinet to maintain operating temperatures within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require conformal coating?\u003c\/strong\u003e Yes, the 140DVO85300C comes standard with conformal coating to protect against corrosive industrial environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the maximum current capacity?\u003c\/strong\u003e The module supports up to 0.5 A per channel, with a total maximum module current of 16 A.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow are faults handled?\u003c\/strong\u003e The module features active electronic fusing that isolates faulty channels autonomously, allowing the remaining outputs to continue functioning.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50969085116668,"sku":"140DVO85300C","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_50c841df-a086-4428-806c-aaa7eafdd186.jpg?v=1786496461","url":"https:\/\/www.electronicplc.com\/products\/schneider-electric-modicon-quantum-140dvo85300c-discrete-output-modules","provider":"Electronic PLC","version":"1.0","type":"link"}