{"product_id":"schneider-electric-modicon-x80-bmenoc0301-ethernet-module-m580","title":"Schneider Electric BMENOC0301 Modicon M580 Ethernet Communication Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric BMENOC0301 is a high-performance 3-port Ethernet communication module designed for the Modicon M580 programmable automation controller (PAC) platform. It serves as a critical interface between the M580 system and various Ethernet-based network devices, supporting both EtherNet\/IP and Modbus TCP communication protocols. This module is engineered to enhance connectivity in medium to large-scale industrial process applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Port Connectivity:\u003c\/strong\u003e Features three RJ45 Ethernet ports for flexible network integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Native support for Modbus TCP and EtherNet\/IP I\/O scanning and messaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Resilience:\u003c\/strong\u003e Integrated multi-port switch with support for Rapid Spanning Tree Protocol (RSTP) to prevent network loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Management:\u003c\/strong\u003e Includes SNMP network administration, bandwidth management, and an FDR (Faulty Device Replacement) server.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Built-in web server for configuration and diagnostics, complemented by front-panel LED indicators (RUN, ERR, ETH MS, ETH NS).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e Supports replacement during system operation without requiring a full power cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e High-speed communication for complex manufacturing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Control:\u003c\/strong\u003e Manages machinery requiring robust Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control:\u003c\/strong\u003e Scalable solution for medium to large-scale industrial processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e Seamless integration into power and energy distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIIoT Readiness:\u003c\/strong\u003e Transparent Ready technology links field devices to higher-level enterprise networks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eBMENOC0301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon M580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e3 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e555 mA @ 3.3 V DC (Internal rack supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMain rack (Ethernet + X-bus slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 61131-2, EN 61000-6-4, EN 61000-6-2, EN 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Requirement:\u003c\/strong\u003e Must be installed on a BME (Ethernet-enabled) backplane. It will not function on a standard BMX (X-Bus only) backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always handle the module using proper electrostatic discharge (ESD) protection measures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Handling:\u003c\/strong\u003e While the module is hot-swappable, ensure the slot is clear of debris before insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use double-shielded twisted pair cabling for optimal performance. Avoid routing Ethernet cables near high-EMI sources such as power lines or motor drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Configuration:\u003c\/strong\u003e When the Ethernet backplane port is enabled, avoid connecting the module directly to the CPU via an external Ethernet cable to prevent network conflicts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the BMENOC0301?\u003c\/h3\u003e\u003cp\u003eThe BMENOC0301 is an Ethernet\/IP and Modbus\/TCP communication module specifically designed for the Modicon M580 PAC system to facilitate high-speed data exchange.\u003c\/p\u003e\u003ch3\u003eIs the BMENOC0301 hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the module supports hot-swapping. It can be replaced while the system is powered, though the new module will initialize with its unique MAC address.\u003c\/p\u003e\u003ch3\u003eWhat are the cabling restrictions?\u003c\/h3\u003e\u003cp\u003eWhen the Ethernet backplane port is enabled, do not connect the module directly to the CPU via an external Ethernet cable, as this may create a network loop or conflict.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50915274064124,"sku":"BMENOC0301","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_cccb2f03-7242-4621-8e07-1d38a31fb9dd.jpg?v=1785822478","url":"https:\/\/www.electronicplc.com\/products\/schneider-electric-modicon-x80-bmenoc0301-ethernet-module-m580","provider":"Electronic PLC","version":"1.0","type":"link"}