{"product_id":"schneider-modicon-tsx-micro-tsxaez414-analog-input-module","title":"Schneider Modicon TSX Micro TSXAEZ414 Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXAEZ414 is a high-precision analog input module designed for the Modicon TSX Micro automation platform. This module features 4 differential channels and utilizes a 16-bit analog-to-digital conversion architecture to provide reliable signal processing in demanding industrial applications. It is engineered to maintain high measurement accuracy while minimizing noise and signal variance, making it suitable for critical process control environments including water treatment, power generation, and chemical manufacturing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 differential high-level analog input channels.\u003c\/li\u003e\n\u003cli\u003e16-bit resolution for precise data acquisition.\u003c\/li\u003e\n\u003cli\u003eRobust 500 VAC electrical isolation between field instrumentation and backplane logic.\u003c\/li\u003e\n\u003cli\u003eLow input impedance of 10 Ohm to support signal integrity over extended cable runs.\u003c\/li\u003e\n\u003cli\u003eOptimized thermal stability with low drift coefficients for both voltage and current loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe TSXAEZ414 is intended for use in industrial automation systems requiring precise monitoring of analog signals. Common applications include loop monitoring, process variable tracking in chemical processing, discrete control in mining operations, and general instrumentation integration within the Modicon TSX Micro ecosystem.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXAEZ414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon TSX Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 High Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcquisition Period\u003c\/td\u003e\n\u003ctd\u003e520 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e85 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment with adequate ventilation to maintain operating temperatures between 0 and 60 deg C.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the module chassis to the system common ground to maintain the integrity of the isolation barrier.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring is securely terminated to prevent intermittent signal loss or loop impedance fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the TSXAEZ414 module?\u003c\/h3\u003e\u003cp\u003eThe TSXAEZ414 is an analog input module for the Schneider Modicon TSX Micro series, used to convert high-level analog signals into 16-bit digital data for processing by the PLC.\u003c\/p\u003e\u003ch3\u003eWhat is the acquisition cycle time for this module?\u003c\/h3\u003e\u003cp\u003eThe module features a fixed acquisition cycle of 520 ms, which balances signal filtering with the data refresh rate required for process control.\u003c\/p\u003e\u003ch3\u003eDoes this module provide electrical isolation?\u003c\/h3\u003e\u003cp\u003eYes, the module includes a 500 VAC isolation barrier that protects the internal backplane logic from field-side voltage spikes or ground loops.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51002219921660,"sku":"TSXAEZ414","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3b27cd43-1a83-46e7-9584-6edd94520d7a.jpg?v=1787337362","url":"https:\/\/www.electronicplc.com\/products\/schneider-modicon-tsx-micro-tsxaez414-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}