{"product_id":"schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","title":"Schneider Electric TSXDSZ08R5 Modicon TSX Micro Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXDSZ08R5 is a dedicated relay output module engineered for the Modicon TSX Micro programmable logic controller series. This module facilitates the interface between low-voltage control logic and higher-voltage field devices, providing 8 independent normally open (NO) relay outputs. It is specifically designed for applications requiring galvanic isolation and the flexibility to switch both AC and DC load circuits, making it a robust solution for industrial automation tasks including motor control, solenoid actuation, and valve management.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Ensures electrical separation between the controller backplane and field-side power circuits, protecting sensitive CPU components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Switching:\u003c\/strong\u003e Supports a broad operating voltage range from 24 to 240 VAC or 24 to 48 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e Features dedicated LED indicators for each channel, providing real-time visual verification of output status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Protection:\u003c\/strong\u003e Includes onboard RC snubber circuitry to suppress voltage spikes generated by inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminals:\u003c\/strong\u003e Equipped with removable screw terminal blocks to simplify field wiring and module replacement without disconnecting individual wires.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for various industrial environments, including energy management, manufacturing process control, and infrastructure automation. Its relay-based design is ideal for interposing logic signals in systems where electrical isolation from the main control bus is a critical safety or operational requirement.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDSZ08R5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e8 x Normally Open (NO) Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24-240 VAC \/ 24-48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current (per channel)\u003c\/td\u003e\n\u003ctd\u003e2.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e10.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Switching Load\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC (contacts to bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 VDC \/ 60 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the module in a location that allows for adequate airflow to maintain the specified operating temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field wiring to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the total load current does not exceed the 10 A module limit to prevent thermal damage.\u003c\/li\u003e\n\u003cli\u003eEnsure that the terminal block is securely seated and screws are tightened to the appropriate torque to maintain reliable contact.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of loads can the TSXDSZ08R5 switch?\u003c\/h3\u003e\u003cp\u003eThe module is designed for both AC and DC loads, supporting 24-240 VAC and 24-48 VDC. It is particularly useful for switching inductive loads such as contactors, relays, and small solenoid valves.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all TSX Micro racks?\u003c\/h3\u003e\u003cp\u003eThe TSXDSZ08R5 is designed specifically for the Modicon TSX Micro backplane. Please consult your system documentation to ensure your specific CPU and rack configuration support this module type.\u003c\/p\u003e\u003ch3\u003eDoes the module require external power for the relays?\u003c\/h3\u003e\u003cp\u003eThe module draws its internal logic power from the backplane, but the field-side load circuits must be powered by an external source appropriate for the connected devices.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51217613783292,"sku":"TSXDSZ08R5","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_03fc6fc4-ece6-498a-a453-6a3d90fa2666.jpg?v=1788376918","url":"https:\/\/www.electronicplc.com\/products\/schneider-modicon-tsx-micro-tsxdsz08r5-digital-output-modules","provider":"Electronic PLC","version":"1.0","type":"link"}