{"product_id":"schneider-telemecanique-tsx-17-tsx1712028-programmable-logic-controllers","title":"Schneider Telemecanique TSX1712028 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eThe Schneider Telemecanique TSX1712028 is a compact, self-contained programmable logic controller (PLC) designed for the TSX 17 series platform. This unit integrates processing capabilities with fixed onboard I\/O, providing a robust solution for localized automation tasks in industrial environments including power plant cooling systems, mining conveyor controls, and automated pumping stations. By utilizing an all-in-one architecture, the TSX1712028 reduces the need for complex external bus cabling, thereby increasing system reliability and simplifying maintenance in critical control loops.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 20-point I\/O configuration: 12 discrete inputs and 8 electromechanical relay outputs.\u003c\/li\u003e\n\u003cli\u003eHigh-speed logic execution: 3.5 microseconds per Boolean instruction for responsive real-time control.\u003c\/li\u003e\n\u003cli\u003eIntegrated power supply: Operates directly from 100-240 V AC line power.\u003c\/li\u003e\n\u003cli\u003eRugged relay outputs: Supports direct switching of AC or DC loads without the need for interposing relays.\u003c\/li\u003e\n\u003cli\u003eOptical isolation: Discrete inputs are internally isolated to protect the internal data bus from field-side voltage transients.\u003c\/li\u003e\n\u003cli\u003eReal-time diagnostics: Front-panel LED indicators provide immediate status monitoring for inputs, outputs, and system health.\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory: Internal storage ensures instruction set retention during power interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis controller is suited for standalone machine control or as a distributed controller within larger legacy Modicon\/Telemecanique automation architectures. Its compact design makes it ideal for space-constrained control panels in industrial infrastructure, small-scale process automation, and auxiliary equipment monitoring.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSX1712028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric \/ Telemecanique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V AC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e12 Channels (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8 Channels (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC \/ 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Relay Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller is mounted in a well-ventilated enclosure to maintain ambient temperatures within the 0-55 deg C range.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect main power before performing any wiring, module insertion, or removal.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for communication and high-speed input lines to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that input voltage polarity matches the specific sink\/source configuration of the input block.\u003c\/li\u003e\n\u003cli\u003eGround the chassis properly to a common industrial earth point to ensure noise immunity and safety.\u003c\/li\u003e\n\u003cli\u003eKeep high-voltage power lines and low-voltage signal lines in separate cable trays to prevent inductive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs the TSX1712028 compatible with modern programming software?\u003c\/strong\u003e\u003cbr\u003eThe TSX 17 series is a legacy platform. Programming typically requires specific legacy Telemecanique software and the appropriate serial communication hardware interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this unit require an external power supply for the inputs?\u003c\/strong\u003e\u003cbr\u003eYes, the 24 V DC discrete inputs require an external power source to function, ensuring electrical isolation from the AC supply.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51232354861308,"sku":"TSX1712028","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3b56bc29-2977-4b24-bdd3-59b73f0a0d20.jpg?v=1788653470","url":"https:\/\/www.electronicplc.com\/products\/schneider-telemecanique-tsx-17-tsx1712028-programmable-logic-controllers","provider":"Electronic PLC","version":"1.0","type":"link"}