{"product_id":"spm-a-synchronizer-woodward-9907-028","title":"SPM-A Synchronizer Woodward 9907-028","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 9907-028\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e9907-028\u003c\/strong\u003e Synchronizer, operates as a dedicated hardware component for automatic phase matching and circuit breaker closure control within generator paralleling architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9907-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard SPM-A Chassis Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-45 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSPM-A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC RMS (+\/-10 percent tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Angle Window\u003c\/td\u003e\n\u003ctd\u003e+\/-10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Matching\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimal Temperature\u003c\/td\u003e\n\u003ctd\u003e10 to 30 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermal Heat Sink Dissipation Profiles \u0026amp; Actuator Loop Feedback\u003c\/h3\u003e\n\u003cp\u003eInternal transformer stages and power conditioning circuits generate minor thermal energy dissipated via natural air convection across the chassis surface. Maintaining reliable thermal heat sink dissipation profiles within the optimal temperature range of 10 to 30 deg C prevents frequency sensing drift during extended synchronizing sequences. High-speed phase detection circuits compute slip frequency and phase angle errors (+\/-10 deg window), driving rapid actuator loop feedback response to governor speed adjust inputs to command precise, transient-free breaker closure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What cable shielding practices apply to the 115\/230 VAC RMS sensing inputs on this module?\u003c\/li\u003e\n\u003cli\u003eA: Potential transformer (PT) bus and generator sensing conductors must use shielded twisted-pair cables with shield drain wires connected to a single chassis ground point to avoid common-mode noise corruption.\u003c\/li\u003e\n\u003cli\u003eQ: How does the lack of integrated voltage matching affect installation requirements?\u003c\/li\u003e\n\u003cli\u003eA: Because the 9907-028 handles phase angle matching and breaker closing without adjusting generator output amplitude, an external automatic voltage regulator (AVR) must manage voltage matching prior to synchronization.\u003c\/li\u003e\n\u003cli\u003eQ: What terminal grounding procedure should be followed for the chassis enclosure?\u003c\/li\u003e\n\u003cli\u003eA: The main enclosure grounding lug must connect directly to the central switchgear ground bus using a low-impedance copper strap to prevent ground potential offsets during switching events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the synchronizer chassis vertically inside the control panel using designated mounting holes to resist industrial vibration.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate surrounding clearance around ventilation slots to support unhindered convective heat transfer.\u003c\/li\u003e\n\u003cli\u003eRoute AC potential sensing leads, breaker trip circuits, and DC governor control cables in separate grounded conduits away from high-power distribution lines.\u003c\/li\u003e\n\u003cli\u003eVerify 115\/230 VAC input voltage selection taps and transformer ratios before applying operating potential to the unit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50738869240060,"sku":"9907-028 REV C","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-028_REV_C1.jpg?v=1785376955","url":"https:\/\/www.electronicplc.com\/products\/spm-a-synchronizer-woodward-9907-028","provider":"Electronic PLC","version":"1.0","type":"link"}