{"product_id":"spw482-13-yokogawa-power-supply-module-new-original-stock","title":"SPW482-13 YOKOGAWA Power Supply Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SPW482-13\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSPW482-13\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power distribution within CENTUM VP and related process control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eSPW482-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eStandard module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e230 VA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e220-240 VAC (+\/- 10%), 50\/60 Hz (+\/- 3 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eInterface\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eExclusive backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Power Stabilization\u003c\/h3\u003e\n\u003cp\u003eThe SPW482-13 is a specialized power supply module engineered exclusively for the Field Control Unit (FCU), FIO Node Unit, and Optical ESB Bus Repeater Unit. It does not function as a generic power source; its output characteristics are strictly matched to the power requirements of these specific Yokogawa platform components. The module supports a dual-redundant configuration, allowing for concurrent installation of two modules to ensure continuous operation and fault tolerance against individual power supply failures within the DCS chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SPW482-13 be used to power generic 24 VDC instruments?\u003c\/p\u003e\n\u003cp\u003eA: No. This module is designed for exclusive use with specific Yokogawa units, including the FCU, FIO Node Unit, and Optical ESB Bus Repeater Unit. It lacks the universal output specifications required for general-purpose instrumentation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for achieving a redundant power configuration?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy is achieved by installing two SPW482-13 modules within the designated slots of the host unit (FCU or FIO Node). The system automatically manages load sharing between the redundant modules to provide high availability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the host unit (FCU or FIO Node) is de-energized before inserting or removing the module to prevent electrical arcing at the exclusive connector interface.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the slot guides and push firmly until the module is fully seated into the backplane; verify that the connection is secure to maintain electrical integrity.\u003c\/li\u003e\n\u003cli\u003eDo not attempt to modify the exclusive connector pins or adapt the module for use in non-specified hardware, as this will lead to immediate damage to the module and host unit.\u003c\/li\u003e\n\u003cli\u003eValidate that the 220-240 VAC supply is within the +\/- 10% tolerance range; power instability outside these limits may cause the module to shut down or exhibit transient performance issues.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49134364786940,"sku":"SPW482-13","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SPW482-132.jpg?v=1779760807","url":"https:\/\/www.electronicplc.com\/products\/spw482-13-yokogawa-power-supply-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}