{"product_id":"ssc50d-f2524-yokogawa-signal-converter-new-original-stock","title":"SSC50D-F2524 YOKOGAWA Signal Converter | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for signal conditioning in distributed control system platforms, the \u003cstrong\u003eYOKOGAWA SSC50D-F2524\u003c\/strong\u003e (\u003cstrong\u003eSSC50D-F2524\u003c\/strong\u003e Signal Converter) provides direct physical signal transition and electrical output conversion. This hardware component executes high-precision conversion of analog voltage and current inputs into standardized output signals, facilitating data processing across process control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSSC50D-F2524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e144 mm x 92 mm x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003e0-10 V, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 300 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Instrumentation and Loop Isolation\u003c\/h3\u003e\n\u003cp\u003eThe SSC50D-F2524 integrates into process control loops requiring channel-to-channel isolation to prevent ground loops and common-mode interference. The module supports 4-20 mA HART loop protocol compliance, ensuring that secondary diagnostic data can be transmitted through the analog signal path. Cold junction compensation (CJC) is managed internally for thermocouple-based applications, while the high-impedance input stage ensures minimal loading on external process sensors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 0-10 V or 4-20 mA output mode configurable via software?\u003c\/p\u003e\n\u003cp\u003eA: The output mode is user-selectable through physical switch settings on the module. Ensure the module is de-energized before altering these configurations to prevent signal transients or erratic output behavior.\u003c\/p\u003e\n\u003cp\u003eQ: Can the SSC50D-F2524 maintain accuracy if the input signal exceeds the rated full-scale range?\u003c\/p\u003e\n\u003cp\u003eA: Operation beyond the specified full-scale range may lead to output saturation or non-linear behavior. The module is calibrated for accuracy within the 0-10 V and 4-20 mA ranges; signals outside these bounds may cause logic errors in the downstream controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and Airflow:\u003c\/strong\u003e Install the unit vertically on a DIN rail to facilitate natural convection cooling. Maintain a clearance of at least 50 mm above and below the module to remain within the operating temperature range of -10 deg C to +60 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e To comply with electromagnetic compatibility standards, use shielded twisted-pair cabling for all analog input and output connections. Terminate the shield at the common grounding point to mitigate induced noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Requirements:\u003c\/strong\u003e The module requires a stable 24 VDC power supply. Use a dedicated power branch with secondary overcurrent protection (fuse or circuit breaker) to prevent damage to the module electronics in the event of a short circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Torque:\u003c\/strong\u003e Tighten terminal block screws according to the specified torque range to ensure mechanical stability. Excessive torque may damage the terminal housing, while insufficient torque may result in increased contact resistance and measurement drift.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49181351805180,"sku":"SSC50D-F2524","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SSC50D-F25241.jpg?v=1781143677","url":"https:\/\/www.electronicplc.com\/products\/ssc50d-f2524-yokogawa-signal-converter-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}