{"product_id":"st7-a-yokogawa-multipoint-status-output-card-new-original-stock","title":"ST7*A YOKOGAWA Multipoint Status Output Card | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for discrete signal distribution in legacy control system platforms, the \u003cstrong\u003eYOKOGAWA ST7*A\u003c\/strong\u003e (\u003cstrong\u003eST7*A\u003c\/strong\u003e Status Output Card) provides direct physical electrical switching for field device monitoring and management. This hardware component serves as the status interface utilized to execute relay-based control logic for peripheral devices such as magnetic valves and industrial motors within CENTUM-XL and μ-XL environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eST7*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to factory marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch rack format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eMultiple relay output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM-XL, μ-XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHorizontal or vertical nests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eStatus Monitoring and Device Management\u003c\/h3\u003e\n\u003cp\u003eThe ST7*A is engineered to provide clear, reliable feedback from field instrumentation to the control system. By utilizing multiple relay outputs, the card enables the CENTUM-XL\/μ-XL systems to track the operational status of critical field hardware. This relay-based architecture provides the necessary electrical isolation between high-power field actuators and the low-voltage control rack, protecting the system from potential back-feed or electrical transients. Its modular design supports flexible mounting configurations, allowing for high-density installation in standard 19-inch control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ST7\u003ci\u003eA handle high-current inductive loads directly? A: The relay contacts are rated for status indication and control-level signals. For large motors or heavy-duty magnetic valves, use the ST7\u003c\/i\u003eA outputs to drive an intermediate power relay or contactor rather than switching the load directly, which prevents contact welding.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 24 VDC power supply range critical for card longevity?\u003c\/p\u003e\n\u003cp\u003eA: Yes, maintaining the voltage within the +\/- 10% tolerance is essential. Operating the module outside this range can cause relay chatter or erratic logic states, which may lead to premature failure of the relay coils.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e The ST7*A supports both horizontal and vertical mounting. Ensure the chosen nest orientation provides adequate clearance for the 24 VDC wiring and that airflow is sufficient to dissipate heat from the relay bank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Termination:\u003c\/strong\u003e Use high-quality, stranded copper wire for all field connections. Verify that wire ferrules are used to prevent stray strands, which could bridge terminals and cause intermittent output status signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Although designed for industrial racks, ensure the rack environment is kept free of conductive contaminants or excessive dust, which could interfere with the long-term reliability of the relay contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the rack chassis to the system protective earth (PE) bus. A solid, low-resistance ground connection is mandatory to ensure that the 24 VDC return path remains stable and that the system meets electromagnetic compatibility (EMC) requirements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49182356635900,"sku":"ST7*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ST7A.jpg?v=1781143675","url":"https:\/\/www.electronicplc.com\/products\/st7-a-yokogawa-multipoint-status-output-card-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}