{"product_id":"tc-hai081-9060029-04-honeywell-experion-hart-analog-input-module","title":"TC-HAI081 9060029-04 Honeywell Experion HART Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell TC-HAI081 (PN: 9060029-04) is an 8-channel high-precision analog input module designed for HART-enabled field devices within the Experion PKS and Series-A I\/O architecture. It simultaneously acquires 4–20 mA analog signals and HART digital communication over the same wiring, enabling operators to access both real-time process values and detailed instrument diagnostics without additional cabling.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTC-HAI081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e9060029-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Fully Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Support\u003c\/td\u003e\n\u003ctd\u003e4–20 mA with HART overlay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e216 × 160 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS \/ Series-A I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Mode Signal Acquisition\u003c\/strong\u003e\u003cbr\u003eCaptures both analog process variables and HART digital diagnostics over a single pair of wires, reducing wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Channel Isolation\u003c\/strong\u003e\u003cbr\u003eIndividual galvanic isolation per channel protects against ground loops and isolates faults between channels and the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Measurement Accuracy\u003c\/strong\u003e\u003cbr\u003e±0.15% full-scale accuracy supports precision control applications such as custody transfer and chemical dosing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Communication\u003c\/strong\u003e\u003cbr\u003eEnables remote configuration, calibration, and diagnostics of smart field instruments directly from the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Compact Design\u003c\/strong\u003e\u003cbr\u003eSlim profile allows 8 isolated channels in a single module slot, maximizing I\/O density within the chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this TC-HAI081 a brand new original module?\u003c\/strong\u003e\u003cbr\u003eYes, it is supplied as 100% brand new, original Honeywell hardware with part number 9060029-04 in factory-sealed packaging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support both analog and HART signals simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes, it reads the 4–20 mA analog signal while also extracting HART digital data from the same loop concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with non-HART transmitters?\u003c\/strong\u003e\u003cbr\u003eYes, it is fully compatible with standard 4–20 mA devices and functions as a high-accuracy analog input module without HART.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of channel isolation?\u003c\/strong\u003e\u003cbr\u003eChannel-to-channel isolation prevents electrical faults or noise on one input from affecting other channels, improving overall system stability and measurement integrity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48907857690876,"sku":"TC-HAI081 9060029-04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/TC-HAI081_9060029-04.jpg?v=1775027466","url":"https:\/\/www.electronicplc.com\/products\/tc-hai081-9060029-04-honeywell-experion-hart-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}